Press the [Enter] keyPress the [ /-] key
WRITE Screen
Writes data saved in GPB-1 to CGY.
You can copy data when replacing the CGY in your machine.
- The data to be written is the
"
BASIC
"
menu and
"
EXPERT
"
menu.
- With the exception, the setting of ACT / INH of
"
Internal
"
on the
"
RECEIVER
"
screen of the GPB-1 menu is written (for CGY760R).
WRITE screen
While data is being written, the Gx LED of the CGY high-speed
blinking (about 5 sec),
It does not high-speed blinking when the data of GPB-1 and CGY
are the same.
Press and hold the [Esc/Page] key
Press and hold the [Esc/Page] key
Opening screen
WARNING
After writing, if the setting is "INH", the internal receiver is operating without
turning off the power supply once. If the receiver is connected while it is op-
erating, the helicopter crashes with inoperable state.
CAUTION
If you press [Ent] start from the opening screen and display the home screen,
the setting data of the connected CGY will be saved in GPB-1. Please save
the setting data to be written again to GPB-1.
Press and hold the [Enter] key
- When copying from another CGY, connect the copy source CGY to the GPB-1 in
advance and let the GPB-1 read the setting data.