MorphoAccess Installation Guide | Edition 11 | April 2019
Copyright © Gallagher Group Limited Page 14
6.2 Supported MorphoAccess Readers
The following MorphoAccess readers and associated firmware versions are supported.
Important Notes:
• For site security, it is recommended that the password on Sigma Bio, Sigma Multi, Sigma Extreme
and MorphoWave readers be changed after readers have been configured.
• Changing default reader settings other than those mentioned in this document may adversely
impact reader functionality.
• Sigma readers preinstalled with Firmware 3.3.1 onwards have fixed IP Addresses (192.168.1.10) for
easier configuration.
• Morpho Biometric Readers have their time synchronised with the Command Centre server daily. By
default, it synchronises at 3:30 am.
• Factory Sigma Readers with Firmware 4.5.1 default to MA5G mode. Sites using Command Centre
versions older than vEL7.80 will need to change the Sigma Reader firmware to MA2G4.5.1 (Legacy
Mode) firmware.
• Please contact Gallagher Technical Support for assistance if any issues arise.
6.2.1 Legacy Morpho Readers
MA100/MA120
MA 100 Biometric Terminal 252265966 3.3.8
MA 120 D Biometric Terminal + MIFARE 1K & 4K
+ DESFire
MA J-Bio/J-Dual
MA J BIO Biometric Terminal
MA J Dual Biometric Terminal + MIFARE 1K & 4K
+ DESFire
MA500,520,521/
OMA520,521
Morpho Biometric Reader MA500 +
Morpho Biometric Reader MA520 + D 293556653 3.9.0
Morpho Biometric Reader MA521 + D
Morpho Biometric Reader OMA520 + D
Morpho Biometric Reader OMA521 + D 260552305 3.9.0
6.2.2 Finger Vein Morpho Readers
Reader Model Description Unit Part No
Finger Vein/VP
Series
Morpho Access VP BIO Reader
Morpho Access VP Dual Reader