TIPS & TROUBLESHOOTING
Install energizer where it can get plenty of sunlight.
Keep solar panel surface clean - periodically use a so cloth with water and a
mild detergent.
Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
Problem Solu ons
Indicator ashing red Ensure energizer is ge ng enough sun
Turn energizer OFF for 3 days, leave in the sun to
charge ba ery.
• Remove ba ery and use a 6 V 1.2 A charger to
charge ba ery.
Indicator ashes red
twice when turned on
then stops
Perform above steps
• Replace ba ery
No voltage on fence Check energizer isn’t faulty;
- disconnect from fence and earth
- measure across fence and earth terminals
with a Gallagher Fence Volt Meter
- if less than 5 kV return energizer for service
- if more than 5 kV the fault is with the fence
or earth system.