13
IMPORTANT BATTERY INFORMATION
Recharging the ba ery Switch the energizer o . Place in sunlight for 3 days
with the ba ery connected OR remove the ba ery
from the energizer and charge the ba ery for 24
hours with a 6 V 1.2 A ba ery charger.
Storing the energizer Switch the energizer o . Store in a well lit area so
solar panel keeps ba ery charged. Recharge ba ery
before and a er storage.
Maintenance free ba ery The ba ery must not be opened and does not
require maintenance.
Ba ery replacement Use only 6 V 4 Ah sealed, valve regulated (VRLA)
ba eries.
Removing the ba ery Switch the energizer o before removing the ba ery.
Disposing the energizer The ba ery must be removed from the energizer
before the energizer is disposed.
Disposing the ba ery Lead acid ba eries must be disposed of safely
according to local regula ons.
PRODUCT SPECIFICATIONS
Ba ery 6 V 4 Ah sealed lead acid (2M1847)
Current draw 15 mA
Stored energy 0.1 J
Output energy 0.07 J
Output voltage (no load) 7 kV