COMMUNICATION
HB_IDL101_E_V222.doc
83
Gantner Instruments Test & Measurement GmbH
Coding <measuring principle>:
Digital Input:
hex 0 no input
hex 1 host input
hex 2 frequency
hex 3 progressive counter
hex 7 interval counter
Digital Output:
hex 0 no output
hex 1 host output
hex 3 process output
Coding <tare/reset/storage>:
hex 0 no tare/reset, no storage of the channels
hex 1 tare/reset valid, no storage of the channels
hex 2 no tare/reset, storage of the channels enabled
hex 3 tare/reset valid, storage of the channels enabled
Register Type Content Length
device information
0300 ........................ro .......................number of variables...................... 2 byte
0301..0303 ...............ro .......................serial number............................... 6 char
0304..030D...............ro .......................location .......................................20 char
Register Type Content Length
device identification
0400..0404 ...............ro .......................vendor name ("Gantner_")............10 char
0405..0408 ...............ro .......................model name ("IDL-101_")............. 8 char
0409..040C ...............ro .......................hw version ("xy.yy_ _ _").............. 8 char
040D..0410...............ro .......................sw version ("xy.yy_ _ _") .............. 8 char
x ... “M“ : monitor program
x ... “U“ : universal program
x ... “T“ : calibration and test program
x ... “A“ : application specific program
x ... “R“ : MODBUS-RTU program
y.yy : version