__________________________________________________________________
Cirrus Perspective™ Line Maintenance Manual Page 9-3
190-00920-00 Rev. E
NOTE
Itisnotnecessarytoremoveallofthegreasefromtheoutputgear,only
theexcessgrease.Donotusesolventstocleantheoutputgear.
1. Removeeachservo.
2. Removeexcessgreasebuild‐upfromthesingle servooutputgearusingalint‐freecloth.
3. Applyathincoatofgreasetotheservooutputgearusingabrushorotherapplicator(see
noteabove).
4. Reinstalltheservos.
5. Rotatecontrolsurfacesthroughtheirrangeofmotiontoensurefreedomofmovement.
9.6 GDCRVSMALTITUDEINSPECTION
OperationwiththeGDCatRVSMaltitudesrequiresanaccuracyinspectionevery12months.
RefertotheGDCFieldCalibrationToolInstructionsifrecalibrationisrequired.Thetablebelow
providesthecriteriaandassociatedactionforaltitudeinspection.
Table9‐1.GDCRVSMAltitudeInspectionCriteria
InspectionPressure‐Altitude
(ft)
Error,|x|(ft)atInspection ActionforAssociatedError
29,000 x≤40 NoAction
40<x≤120 UseFieldCalibration Tool
120<x ReplaceUnit
35,000 x≤40 NoAction
40<x≤120 UseFieldCalibration Tool
120<x ReturnUnittoGarmin
41,000 x≤40 NoAction
40<x≤120 UseFieldCalibration Tool
120<x ReturnUnittoGarmin