190-02246-10 GI 275 Part 23 AML STC Installation Manual
Rev. 11 Page C-4
C.2 ADC
The air data computers listed in Table C-3 are compatible with the GI 275.
Table C-3 Compatible Air Data Computers
Mfr Model Data Format Interfacing Equipment Configuration Information Notes
Garmin
Internal
If another ADC is configured, the internal ADC must be configured as
ADC 2 and must be set as the default. Refer to Section 5.5.4.
Only available on GI 275 ADAHRS
and ADAHRS+AP units.
Other GI 275 HSDB
Crossfills data from a different
GI 275 interfaced to an ADC.
GSU 75 ARINC 429
GDC 72 ARINC 429
GDC 74 ARINC 429
G500/G600 TXi HSDB Interfaces page Standby Instrument: GI 275
TXi software v3.02 or later is
required for GI 275 software v2.05
or earlier.
TXi software v3.10 or later is
required for GI 275 software v2.10
or later.