WIRELESS SITE MANAGER DISPLAYS COMM ERROR FOR A SINGLE
GASMAX/TX
Network Identifier does not match.
GASMAX/TX device ID and WSM assigned channel device ID do not match.
Distance between gas monitor and WSM too great for reliable communications
WSM beacon not set for SERVER if primary network manager
Antenna connection compromised or antenna broken.
WIRELESS SITE MANAGER DISPLAYS COMM ERROR FOR ALL GASMAX/TX
Network Identifiers do not match.
No synchronizing beacon signal. Verify C2/TX RF Mode = SERVER and verify GASMAX/TX “Server
in Range” icon displayed.
RF signal attenuated. Check C2/TX WSM antenna connection, cable and remote antenna (if
installed). Place a GASMAX/TX in close proximity with the C2/TX WSM and check for proper
operation.