Programming the Panel 24
High Level Rpts (0101-cs phone 1, 0111-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
When this setting is on, the panel reports to the central station events that
involve a high-level security risk, including the following conditions:
Fire, Police, Auxiliary, Duress, and Freeze alarms
No Activity
Receiver Failure (or jam)
System Tamper (40 incorrect keystrokes or touchpad supervisory),
Entering or exiting Sensor Test mode
Note
For UL 1635 listed installations, this feature must be set to on for the programmed
phone number.
¾ To turn High-Level Reports off or on:
1. With the display showing HIGH LEVEL RPTS
OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.
Low Level Rpts (0102-cs phone 1, 0112-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
When this setting is on, the panel reports non-alarm conditions to the central
station, including the following conditions:
Force Armed
Hardwire Zone Trouble (open or short)
Supervisory (wireless devices)
Low Battery (wireless devices)
Other non-alarm related conditions
Note
For UL 1635 listed installations, this feature must be set to on for the programmed
phone number.
¾ To turn Low-Level Reports off or on:
1. With the display showing LOW LEVEL RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.
Open/Close Rpts (0103-cs phone 1, 0113-cs phone 2)
Phones-CS Phone 1-2 (Default=off)
When this setting is on, the panel sends a report when the system is armed
(closed) or disarmed (opened).
Note
To use this feature, the Opening Reports and Closing Reports settings under the
REPORTING menu must be turned on.
¾ To turn Opening/Closing Reports off or
on:
1. With the display showing OPEN/CLOSE RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.
Backup (0104-cs phone 1, 0114-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
This setting determines whether or not the panel uses another programmed
central station phone number for reporting if three initial attempts are unsuc-
cessful.
CS Phone 1 is backed up by CS Phone 2, and CS Phone 2 is backed up by
CS Phone 1. The panel makes up to 16 attempts (8 per phone number), alter-
nating between the two programmed phone numbers.
For example, if Backup is on and three failed reporting attempts occur using
CS Phone 1, the panel switches to CS Phone 2 for three more reporting
attempts. If these attempts fail, the panel switches back to CS Phone 1 for
five more reporting attempts and, if necessary, switches back to CS Phone 2
for five final attempts.
¾
To turn Backup off or on:
1. With the display showing BACKUP OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE 60-806-95R-16Z - Security Concord Express System Control Panel and is the answer not in the manual?

GE 60-806-95R-16Z - Security Concord Express System Control Panel Specifications

General IconGeneral
BrandGE
Model60-806-95R-16Z - Security Concord Express System Control Panel
CategorySecurity System
LanguageEnglish

Related product manuals