Programming the Panel
27
Phone Test (02000)
Phones Options-Global (Default=on)
This setting determines if the user can test the communication from the panel
to the central station (or a pager). When this feature is on, the user can test
communications at any time by entering
8 + CODE + 2.
Note
For UL 1635 listed installations, this feature must be set to on.
¾ To turn the Phone Test setting off or on:
1. With the display showing
PHONE TEST OFF/
ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press ƒ and the display shows the new set-
ting.
Auto Phone Test (02001)
Phones Options-Global (Default=off)
This setting determines if the panel sends a phone test automatically to the
central station (or a pager) on a predetermined schedule. (Refer to the “Phone
Test Freq.” and “Next Phone Test” settings found under
TIMERS—GLOBAL).
Note
For UL 1635 listed installations, this feature must be set to on.
¾ To turn Automatic Phone Test off or on:
1. With the display showing
AUTO PHONE TEST
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.
Auto Test Reset (02002)
Phones Options-Global (Default=on)
This setting determines whether or not the Auto Phone Test interval is reset
after any successful report to the central monitoring station. Refer to the
“Phone Test Freq.” and “Next Phone Test” settings found under
TIMERS—GLO-
BAL.
When this feature is on, the panel considers any successful report to the cen-
tral station to be a successful phone test. Thus, any successful panel report to
the central monitoring station resets the Next Phone Test setting to the Phone
Test Freq. value. The panel only conducts an Auto Phone Test if no other
reports are made during the Phone Test Freq. time period.
When this feature is off, an Auto Phone Test is always conducted according to
the Phone Test Freq. setting, even if the panel makes other reports to the cen-
tral monitoring station during that time period.
Note
Phone Test Freq must be set to 2 or higher for this feature to work.
¾ To turn Auto Test Reset off or on:
1.
With the display showing AUTO TEST RESET
OFF/ON
(current setting), press 1 (off) or
2 (on). The display flashes the entered
setting.
2. Press ƒ and the display shows the new
setting.
Comm Failure (02003)
Phones Options-Global (Default=on)
When this setting is on, the panel activates trouble beeps to alert users on the
premises that communication to the central station has failed. Failure notifica-
tion occurs after the third unsuccessful reporting attempt to the central station
(or pager).
Note
For UL 1635 listed installations, this feature must be set to on.
¾ To turn Communication Failure notifica-
tion off or on:
1. With the display showing
COMM FAILURE
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press ƒ and the display shows the new set-
ting.
DTMF Dialing (02004)
Phones Options-Global (Default=on)
This setting determines whether the panel uses DTMF tones (on) or pulse (off)
for dialing programmed phone numbers.
¾
To turn DTMF Dialing off or on:
1. With the display showing
DTMF DIALING
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press
ƒ and the display shows the new set-
ting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE 60-806-95R-16Z - Security Concord Express System Control Panel and is the answer not in the manual?

GE 60-806-95R-16Z - Security Concord Express System Control Panel Specifications

General IconGeneral
BrandGE
Model60-806-95R-16Z - Security Concord Express System Control Panel
CategorySecurity System
LanguageEnglish

Related product manuals