Programming the Panel
45
Options Menu
The OPTIONS menu lets you set up the system for downloading and silent arming, and lets you
adjust alphanumeric touchpad display brightness.
System Master Code (110)
User Codes (Default=1234)
The System Master Code performs
all system operations and user pro-
gramming.
¾ To change the System Master Code:
1. With the display showing USER CODES, press ƒ then B. The display shows SYSTEM MAS-
TER CODE
.
2. Press
ƒ and the display shows SYSTEM MASTER nnnn (current code).
3. Enter a new 4-digit code. The display flashes the entered code. Press
ƒ and the display
shows the new code.
Downloading (20)
Options (Default=on)
This setting determines whether or not the
panel can communicate with ToolBox software
for programming the system from off-site.
Note
The panel must have a Downloader phone num-
ber and Downloader code programmed and be
connected to a phone line for this feature to work.
¾ To turn Downloading off or on:
1. Enter user programming with the system master code. The display shows
TIME AND DATE.
2. Press
A or B until the display shows OPTIONS.
3. Press
ƒ and the display shows DOWNLOADING OFF/ON (current setting).
4. Press
1 (off) or 2 (on). The display flashes the entered selection. Press ƒ
and the display shows the new setting.
Silent Arming (21)
Options (Default=off)
This setting determines whether the partition
arms the system with (off) or without (on)
sounding status beeps from sirens and the
touchpad.
Note
Turning this feature on will double the exit time.
This option is not available when SIA False Alarm
Reduction (0003) is on.
¾ To turn Silent Arming off or on:
1. Enter user programming mode with the system master code. The display
shows
TIME AND DATE.
2. Press
A or B until the display shows OPTIONS.
3. Press
ƒ, then B and the display shows SILENT ARMING OFF/ON (current set-
ting).
4. Press
1 (off) or 2 (on). The display flashes the entered selection. Press ƒ
and the display shows the new setting.
Touchpad Brightness (22)
Options (Default=2)
This setting lightens or darkens the background
on touchpad displays. Each touchpad display
can be set independently to compensate for
lighting conditions in the touchpad location.
¾
To adjust Touchpad Brightness:
1. Enter user programming mode with the system master code. The display
shows TIME AND DATE.
2. Press
A or B until the display shows OPTIONS.
3. Press
ƒ, then B twice and the display shows TOUCHPAD BRIGHTNESS n (cur-
rent setting).
4. Enter a setting from 0 (darkest background) to 3 (brightest background). The
display flashes the entered selection. Press
ƒ and the display shows the new
setting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE 60-806-95R-16Z - Security Concord Express System Control Panel and is the answer not in the manual?

GE 60-806-95R-16Z - Security Concord Express System Control Panel Specifications

General IconGeneral
BrandGE
Model60-806-95R-16Z - Security Concord Express System Control Panel
CategorySecurity System
LanguageEnglish

Related product manuals