– 41 –
PoZer Cords
All new cords are required for both series of
Zonelines. They are redesigned to eliminate the AC
jumper wires.
15 amp – No DC Harness
20 amp – Single Wire DC Harness
30 amp – Double Wire DC Harness
ICR System
The Internal Condensate Removal system consists of
a small pump that is driven by the main board. The
board supplies line voltage to the pump. *Defrost
water that is collected in the rear base pan is
pumped up into a trough that rests along the length
of the indoor coil. Water from the trough drips
down the indoor coil to add moisture to the indoor
air and to reduce the amount of water in the base
pan.
*ONLY during Heat Pump Mode.