3300/16 Dual Vibration Monitor Operation Manual
22
12. Alarm Setpoint Adjustment
12.1 Alert and Danger Setpoint Adjustment
1. Open front panel.
2. Set the adjust channel A switch
(AA) to the left (ON). The left
(Channel A) bargraph will start
flashing the channel A vibration
signal.
3. Press and hold the ALERT or
DANGER switch on the front
panel. Use the outer meter scale.
4. Press the () or () switches on
the System Monitor to adjust the
setpoint level up or down.
Caution
Changing Alarm Setpoints
will change the trip levels of
the machine.