Sievers 500 RL On-Line
Total Organic Carbon Analyzer
Operation and
Maintenance Manual
Firmware Version 2.10 or later
GE Analytical Instruments
6060 Spine Road
Boulder, CO 80301 USA
phone 800.255.6964 • 303.444.2009
fax 303.444.9543 DLM 74001-04 Rev. A
www.geinstruments.com
Printed in USA ©2010

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the GE Sievers 500 RL and is the answer not in the manual?

GE Sievers 500 RL Specifications

General IconGeneral
CategoryTotal Organic Carbon (TOC) Analyzer
Power Requirements100-240 VAC, 50/60 Hz
Detection Limit0.03 ppb
Measurement Range0.03 ppb to 50, 000 ppb (µg/L)
Operating Temperature5°C to 45°C
Weight35 lbs (16 kg)

Summary

Installation

Install Power and Control Wiring

Details the process of connecting power and control wiring to the analyzer's electrical enclosure.

Connect the Sample Inlet and Outlet Ports

Guides the connection of sample inlet and outlet ports to the analyzer system for analysis.

Fill the DI Water Cartridge

Provides instructions on how to properly fill the DI water cartridge with DI water.

Configure Basic Analyzer Settings

Guides the configuration of essential analyzer settings for operation, including security features.

Basic Analyzer Operation

Taking TOC Measurements

Explains how to initiate and perform TOC measurements using the analyzer's current settings.

Reviewing Warnings and Errors

Guides the review and printing of warnings and errors to diagnose analyzer issues.

Password Protection and DataGuard

Enabling Password Protection

Ensures authorized personnel change parameters; requires default user/password upon enabling.

Enabling DataGuard

Guides the activation of DataGuard, recommending new admin account creation and default account inactivation.

Viewing, Exporting, and Printing Audit Trails

Details how to view, export, and print the audit trail of user activities for security compliance.

Calibration and System Protocols

Performing a Single-Point Calibration

Guides the user through the procedure for performing a single-point calibration on the analyzer.

Performing a Multi-Point Calibration

Details the procedure for performing a multi-point calibration, an alternative to single-point calibration.

Accuracy, Precision, and Calibration Verification

Guides the procedure for verifying the analyzer's calibration accuracy and precision.

System Suitability Verification

Guides the system suitability verification procedure to ensure analyzer performance.

Maintenance

Replacing Consumables and Maintenance Items

Guides the routine replacement of consumables and maintenance items for optimal analyzer performance.

Replacing the UV Lamp

Provides step-by-step instructions for replacing the UV lamp in the analyzer.

Replacing the Sample Pump Tubing and Pump Heads

Guides the replacement of sample pump tubing and pump heads, critical for flow rates.

Troubleshooting

Contact Technical Support

Provides contact information for GE Analytical Instruments Technical Support for further assistance.

Connecting to a PC

Related product manuals