5.1 E-CELL STACK™ MAXIMUM POWER REQUIREMENTS
INPUT
VOLTAGE
INPUT
CURRENT
MAX
POWER
100-600V 0.5-4.5A 2.7 kW
5.2 OPERATING CURRENT
In order for the E-Cell Stack™ to produce high quality water, the current flow must be
sufficient for the ionic load in the feed water. In general, more current is required as the
ionic load increases. More current is also required for silica removal.
6. MECHANICAL AND HYDRAULIC
Do not adjust the bolts on the E-Cell Stack
side and end plates as tampering may result in
permanent damage to the E-Cell Stack
and voids the warranty.
Care must be taken to protect against water hammer. Feed Water pressure should never
exceed 100 psi (6.8 bar)