rev.1.1 Page 3-7
3.5 E-CELL STACK™
TECHNICAL DATA SHEET
Design Pressure of E-Cell Stack
...........................................................................100 psig (6.8 Bar)
Membrane Manufacturers ............................................................ Asahi Glass Corporation (AGC)
Ion Exchange Manufacturers............................................................................Mitsubishi Chemical
Model Designations ..............MK-2E, MK-2Pharm, MK-2PharmHT, MK-2Mini, MK-2MiniHT
Anode Material......................................................................................................................IrO
x
/TiO
2
on Ti
Cathode Material ................................................................................................................Stainless Steel
Operating Weight ................................................................................................................. See Cutsheet
3.6 PERFORMANCE DATA
Maximum System Product Flow Rate ........................................................................ See Cutsheet
Minimum System Product Flow Rate.......................................................................... See Cutsheet
MK-2E, MK2-Pharm, MK-2PharmHT Stack™ Product Flow Rate.................................................
...................................................................................................................Minimum 7.5 gpm (1.70 m
3
/hr)
.................................................................................................................. Nominal 15.0 gpm (3.41 m
3
/hr)
...............................................................................................................Maximum 20.0 gpm (4.54 m
3
/hr)
MK-2Mini, MK-2MiniHT Stack™ Product Flow Rate...........................................................................
................................................................................................................. Minumum 2.5 gpm (0.57 m
3
/hr)
.....................................................................................................................Nominal 5.0 gpm (1.14 m
3
/hr)
..................................................................................................................Maximum 6.7 gpm (1.52 m
3
/hr)
Recovery.............................................................................................................................................. 90-95%
MK-2E, MK-2Pharm, MK-2PharmHT Stack™ voltage input ...............................100 V - 600 V
MK-2Mini, MK-2MiniHT Stack™ voltage input .........................................................100 V - 300 V
Stack™ current input ...................................................................................................................0.5A-4.5A