Connecting multiple keypads with RJ45 cables
Adhere to all installation guidelines while making connections, including your local codes and those provided
in Installation guidelines on page 8.
Figure 10. KTD-405, KTD-405-2D, and KTD-405A connections via RJ45 cables
12 VDC (observe polarity, if provided transformer and plug not used)
RS-422 IN (data in from devices such as alarm units, ASCII converters, or keypads (see guidelines))
RS-422 OUT (data out to devices such as domes, switchers, other keypads (not KTD-405s))
AUDIO OUT (to speaker and speaker shield)
RS-485 OUT (data out to devices such as multiplexers or DVMRes; ground at mux/DVMRe)
RS-485 to I/O box of additional keypad via RJ45 cable
KEYPAD IN (RS-422 and RS-485 data in from keypad; RS-422 data and power out to keypad)
AUDIO IN (from keypad)
PIN 1 to RS-485 shield (ground one end only)
PIN 3 to RS-485 A
PIN 6 to RS-485 B (PINs 2, 4, 5, 7, and 8 are not connected.)
78910653214
POWER
12 VDC
BIAS
SWITCH
78910653214
RS485
A
B
A
B
+
AUDIO KEYPAD RS485 RS485
A
B
RS422 IN
RS422 OUT
SPEAKER SHIELD
SPEAKER
REMOVABLE
TERMINAL STRIP
EARTH GROUND
78910653214
78910653214
POWER
12 VDC
BIAS
SWITCH
78910653214
RS485
A
B
A
B
+
AUDIO KEYPAD RS485 RS485
A
B
RS422 IN
RS422 OUT
SPEAKER SHIELD
SPEAKER
REMOVABLE
TERMINAL STRIP
EARTH GROUND
12345678
Observe polarity for:
•audio
•RS-422
•RS-485
12 VDC power. Transformer must have a
positive center-polarity plug
Note: When using multiple keypads, you can
connect CyberDomes and other receivers to
the RS-422 output from any keypad.Only one
RS communication can be chained together,
if both are hooked up on 405 I/O boxes then
performance will degrade or it will not work
at all.