2-8 N60 Network Stability and Synchrophasor Measurement System GE Multilin
2.2 ORDER CODES 2 PRODUCT DESCRIPTION
2
2.2ORDER CODES 2.2.1 OVERVIEW
The N60 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-
ules: power supply, CPU, CT/VT, digital input and output, transducer input and output, and inter-relay communications.
Each of these modules can be supplied in a number of configurations specified at the time of ordering. The information
required to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).
Order codes are subject to change without notice. See the GE Multilin ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
for the latest N60 ordering options.
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules
(enhanced diagnostic CT/VT modules or HardFiber process bus modules). The order code options are described in the fol-
lowing sub-sections.
2.2.2 ORDER CODES WITH ENHANCED CT/VT MODULES
The order codes for the units are shown below.
Table 2–4: N60 ORDER CODES
N60 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal Mount
BASE UNIT N60 | | | | | | | | | | | Base Unit
CPU T | | | | | | | | | | RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U | | | | | | | | | | RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
V | | | | | | | | | | RS485 and Three 10/100Base-T (SFP with RJ45)
SOFTWARE 00 | | | | | | | | | No software options
03 | | | | | | | | | IEC 61850
06 | | | | | | | | | Phasor measurement unit (PMU)
07 | | | | | | | | | IEC 61850 and phasor measurement unit (PMU)
14 | | | | | | | | | Two phasor measurement units (PMUs)
15 | | | | | | | | | IEC 61850 and two phasor measurement units (PMUs)
16 | | | | | | | | | Four phasor measurement units (PMUs)
17 | | | | | | | | | IEC 61850 and four phasor measurement units (PMUs)
A0 | | | | | | | | | CyberSentry Lvl 1
A3 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850
A6 | | | | | | | | | CyberSentry Lvl 1 and phasor measurement unit (PMU)
A7 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
AE | | | | | | | | | CyberSentry Lvl 1 and two phasor measurement units (PMUs)
AF | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
AG | | | | | | | | | CyberSentry Lvl 1 and four phasor measurement units (PMUs)
AH | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
B0 | | | | | | | | | IEEE 1588
B3 | | | | | | | | | IEEE 1588 and IEC 61850
B6 | | | | | | | | | IEEE 1588 and phasor measurement unit (PMU)
B7 | | | | | | | | | IEEE 1588 and IEC 61850 and phasor measurement unit (PMU)
BE | | | | | | | | | IEEE 1588 and two phasor measurement units (PMUs)
BF | | | | | | | | | IEEE 1588 and IEC 61850 and two phasor measurement units (PMUs)
BG | | | | | | | | | IEEE 1588 and four phasor measurement units (PMUs)
BH | | | | | | | | | IEEE 1588 and IEC 61850 and four phasor measurement units (PMUs)
C0 | | | | | | | | | Parallel Redundancy Protocol (PRP)
C3 | | | | | | | | | PRP and Ethernet Global Data (EGD)
C6 | | | | | | | | | PRP and PMU
C7 | | | | | | | | | PRP, IEC 61850, and PMU
CE | | | | | | | | | PRP and two PMUs
CF | | | | | | | | | PRP, IEC 61850, and two PMUs
CG | | | | | | | | | PRP and four PMUs
CH | | | | | | | | | PRP, IEC 61850, and four PMUs
D0 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1
D3 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
D6 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and phasor measurement unit (PMU)
D7 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
DE | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and two phasor measurement units (PMUs)
DF | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
DG | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and four phasor measurement units (PMUs)
DH | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
E0 | | | | | | | | | IEEE 1588 and PRP
E3 | | | | | | | | | IEEE 1588, PRP, and IEC 61850
E6 | | | | | | | | | IEEE 1588, PRP, and PMU
E7 | | | | | | | | | IEEE 1588, PRP, IEC 61850, and PMU
EE | | | | | | | | | IEEE 1588, PRP, and two PMUs
EF | | | | | | | | | IEEE 1588, PRP, IEC 61850, and two PMUs
EG | | | | | | | | | IEEE 1588, PRP, and four PMUs
EH | | | | | | | | | IEEE 1588, PRP, IEC 61850, and four PMUs
F0 | | | | | | | | | PRP and CyberSentry Lvl1
F3 | | | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850
F6 | | | | | | | | | PRP, CyberSentry Lvl 1, and PMU
F7 | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and PMU
FE | | | | | | | | | PRP, CyberSentry Lvl 1, and two PMUs
FF | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
FG | | | | | | | | | PRP, CyberSentry Lvl 1, and four PMUs
FH | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
G0 | | | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1
G3 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G6 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and PMU
G7 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and PMU
GE | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, two PMUs
GF | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
GG | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, four PMUs
GH | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
I0|||| |||| |Six PMUs
I1 | | | | | | | | | Six PMUs + IEC 61850
I2 | | | | | | | | | Six PMUs + CyberSentry Lvl 1
I3 | | | | | | | | | Six PMUs + IEC 61850 + CyberSentry Lvl 1
I4 | | | | | | | | | Six PMUs + IEEE 1588
I5 | | | | | | | | | Six PMUs + IEEE 1588 + IEC 61850
I6 | | | | | | | | | Six PMUs + PRP
I7 | | | | | | | | | Six PMUs + PRP + IEC 61850
I8 | | | | | | | | | Six PMUs + IEEE 1588 + CyberSentry Lvl 1
I9 | | | | | | | | | Six PMUs + IEEE 1588 + CyberSentry Lvl 1 + IEC 61850
IA | | | | | | | | | Six PMUs + PRP + IEEE 1588
IB | | | | | | | | | Six PMUs + PRP + IEEE 1588 + IEC 61850
IC | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1
ID | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEC 61850
IE | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588
IF | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588 + IEC 61850
IG | | | | | | | | | Six PMUs + IEC 60870-5-103
IH | | | | | | | | | Six PMUs + IEC 60870-5-103 + IEC 61850