2-10 N60 Network Stability and Synchrophasor Measurement System GE Multilin
2.2 ORDER CODES 2 PRODUCT DESCRIPTION
2
2.2.3 ORDER CODES WITH PROCESS BUS MODULES
The order codes for units with the process bus module are shown below.
Table 2–5: N60 ORDER CODES (WITH PROCESS BUS)
N60 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal Mount
BASE UNIT N60 | | | | | | | | | | | Base Unit
CPU T | | | | | | | | | | Three Multi-mode fiber 100Base-FX (SFP with LC)
U | | | | | | | | | | Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
V | | | | | | | | | | Three 10/100Base-T (SFP with RJ45)
SOFTWARE 00 | | | | | | | | | No software options
03 | | | | | | | | | IEC 61850
06 | | | | | | | | | Phasor measurement unit (PMU)
07 | | | | | | | | | IEC 61850 and phasor measurement unit (PMU)
14 | | | | | | | | | Two phasor measurement units (PMUs)
15 | | | | | | | | | IEC 61850 and two phasor measurement units (PMUs)
16 | | | | | | | | | Four phasor measurement units (PMUs)
17 | | | | | | | | | IEC 61850 and four phasor measurement units (PMUs)
A0 | | | | | | | | | CyberSentry Lvl 1
A3 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850
A6 | | | | | | | | | CyberSentry Lvl 1 and phasor measurement unit (PMU)
A7 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
AE | | | | | | | | | CyberSentry Lvl 1 and two phasor measurement units (PMUs)
AF | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
AG | | | | | | | | | CyberSentry Lvl 1 and four phasor measurement units (PMUs)
AH | | | | | | | | | CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
B0 | | | | | | | | | IEEE 1588
B3 | | | | | | | | | IEEE 1588 and IEC 61850
B6 | | | | | | | | | IEEE 1588 and phasor measurement unit (PMU)
B7 | | | | | | | | | IEEE 1588 and IEC 61850 and phasor measurement unit (PMU)
BE | | | | | | | | | IEEE 1588 and two phasor measurement units (PMUs)
BF | | | | | | | | | IEEE 1588 and IEC 61850 and two phasor measurement units (PMUs)
BG | | | | | | | | | IEEE 1588 and four phasor measurement units (PMUs)
BH | | | | | | | | | IEEE 1588 and IEC 61850 and four phasor measurement units (PMUs)
C0 | | | | | | | | | Parallel Redundancy Protocol (PRP)
C3 | | | | | | | | | PRP and Ethernet Global Data
C6 | | | | | | | | | PRP and PMU
C7 | | | | | | | | | PRP, IEC 61850, and PMU
CE | | | | | | | | | PRP and two PMUs
CF | | | | | | | | | PRP, IEC 61850, and two PMUs
CG | | | | | | | | | PRP and four PMUs
CH | | | | | | | | | PRP, IEC 61850, and four PMUs
D0 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1
D3 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
D6 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and phasor measurement unit (PMU)
D7 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
DE | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and two phasor measurement units (PMUs)
DF | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
DG | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and four phasor measurement units (PMUs)
DH | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
E0 | | | | | | | | | IEEE 1588 and PRP
E3 | | | | | | | | | IEEE 1588, PRP, and IEC 61850
E6 | | | | | | | | | IEEE 1588, PRP, and PMU
E7 | | | | | | | | | IEEE 1588, PRP, IEC 61850, and PMU
EE | | | | | | | | | IEEE 1588, PRP, and two PMUs
EF | | | | | | | | | IEEE 1588, PRP, IEC 61850, and two PMUs
EG | | | | | | | | | IEEE 1588, PRP, and four PMUs
EH | | | | | | | | | IEEE 1588, PRP, IEC 61850, and four PMUs
F0 | | | | | | | | | PRP and CyberSentry Lvl1
F3 | | | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850
F6 | | | | | | | | | PRP, CyberSentry Lvl 1, and PMU
F7 | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and PMU
FE | | | | | | | | | PRP, CyberSentry Lvl 1, and two PMUs
FF | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
FG | | | | | | | | | PRP, CyberSentry Lvl 1, and four PMUs
FH | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
G0 | | | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1
G3 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G6 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and PMU
G7 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and PMU
GE | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, two PMUs
GF | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
GG | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, four PMUs
GH | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
I0|||| |||| |Six PMUs
I1 | | | | | | | | | Six PMUs + IEC 61850
I2 | | | | | | | | | Six PMUs + CyberSentry Lvl 1
I3 | | | | | | | | | Six PMUs + IEC 61850 + CyberSentry Lvl 1
I4 | | | | | | | | | Six PMUs + IEEE 1588
I5 | | | | | | | | | Six PMUs + IEEE 1588 + IEC 61850
I6 | | | | | | | | | Six PMUs + PRP
I7 | | | | | | | | | Six PMUs + PRP + IEC 61850
I8 | | | | | | | | | Six PMUs + IEEE 1588 + CyberSentry Lvl 1
I9 | | | | | | | | | Six PMUs + IEEE 1588 + CyberSentry Lvl 1 + IEC 61850
IA | | | | | | | | | Six PMUs + PRP + IEEE 1588
IB | | | | | | | | | Six PMUs + PRP + IEEE 1588 + IEC 61850
IC | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1
ID | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEC 61850
IE | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588
IF | | | | | | | | | Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588 + IEC 61850
IG | | | | | | | | | Six PMUs + IEC 60870-5-103
IH | | | | | | | | | Six PMUs + IEC 60870-5-103 + IEC 61850
II | | | | | | | | | Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588
IJ | | | | | | | | | Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + IEC 61850
IK | | | | | | | | | Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + CyberSentry Lvl 1
IL | | | | | | | | | Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + CyberSentry Lvl 1 + IEC 61850
J0 | | | | | | | | | IEC 60870-5-103
J3 | | | | | | | | | IEC 60870-5-103 + IEC 61850
J6 | | | | | | | | | IEC 60870-5-103 + PMU
J7 | | | | | | | | | IEC 60870-5-103 + IEC 61850 + PMU
JE | | | | | | | | | IEC 60870-5-103 + two PMUs
JF | | | | | | | | | IEC 60870-5-103 + IEC 61850 + two PMUs
JG | | | | | | | | | IEC 60870-5-103 + four PMUs
JH | | | | | | | | | IEC 60870-5-103 + IEC 61850 + four PMUs
K0 | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103
K3 | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850
K6 | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + PMU
K7 | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + PMU
KE | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + two PMUs
KF | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + two PMUs
KG | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + four PMUs
KH | | | | | | | | | IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + four PMUs
L0 | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1
L3 | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850
L6 | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + PMU
L7 | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + PMU
LE | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + two PMUs
LF | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + two PMUs
LG | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + four PMUs
LH | | | | | | | | | IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + four PMUs
MOUNT/COATING H | | | | | | | | Horizontal (19” rack)
A | | | | | | | | Horizontal (19” rack) with harsh environmental coating