GE Multilin N60 Network Stability and Synchrophasor Measurement System B-53
APPENDIX B B.4 MEMORY MAPPING
B
A754 ...Repeated for Non-Volatile Latch 8
A760 ...Repeated for Non-Volatile Latch 9
A76C ...Repeated for Non-Volatile Latch 10
A778 ...Repeated for Non-Volatile Latch 11
A784 ...Repeated for Non-Volatile Latch 12
A790 ...Repeated for Non-Volatile Latch 13
A79C ...Repeated for Non-Volatile Latch 14
A7A8 ...Repeated for Non-Volatile Latch 15
A7B4 ...Repeated for Non-Volatile Latch 16
Frequency Rate of Change (Read/Write Setting) (4 Modules)
A900 Frequency Rate of Change 1 Function 0 to 1 --- 1 F102 0 (Disabled)
A901 Frequency Rate of Change 1 OC Supervision 0 to 30 pu 0.001 F001 200
A902 Frequency Rate of Change 1 Min 20 to 80 Hz 0.01 F001 4500
A903 Frequency Rate of Change 1 Max 20 to 80 Hz 0.01 F001 6500
A904 Frequency Rate of Change 1 Pickup Delay 0 to 65.535 s 0.001 F001 0
A905 Frequency Rate of Change 1 Reset Delay 0 to 65.535 s 0.001 F001 0
A906 Frequency Rate of Change 1 Block 0 to 4294967295 --- 1 F300 0
A908 Frequency Rate of Change 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
A909 Frequency Rate of Change 1 Events 0 to 1 --- 1 F102 0 (Disabled)
A90A Frequency Rate of Change 1 Source 0 to 5 --- 1 F167 0 (SRC 1)
A90B Frequency Rate of Change 1 Trend 0 to 2 --- 1 F224 0 (Increasing)
A90C Frequency Rate of Change 1 Pickup 0.1 to 15 Hz/s 0.01 F001 50
A90D Frequency Rate of Change 1 OV Supervision 0.1 to 3 pu 0.001 F001 700
A90E Frequency Rate of Change 1 Reserved (3 items) 0 to 1 --- 1 F001 0
A911 ...Repeated for Frequency Rate of Change 2
A922 ...Repeated for Frequency Rate of Change 3
A933 ...Repeated for Frequency Rate of Change 4
IEC 61850 Received Analog Settings (Read/Write) (32 Modules)
AA00 IEC 61850 GOOSE analog 1 default value –1000000 to 1000000 --- 0.001 F060 1000
AA02 IEC 61850 GOOSE analog input 1 mode 0 to 1 --- 1 F491 0 (Default Value)
AA03 IEC 61850 GOOSE analog input 1 units --- --- --- F207 (none)
AA05 IEC 61850 GOOSE analog input 1 per-unit base 0 to 999999999.999 --- 0.001 F060 1
AA07 ...Repeated for IEC 61850 GOOSE analog input 2
AA0E ...Repeated for IEC 61850 GOOSE analog input 3
AA15 ...Repeated for IEC 61850 GOOSE analog input 4
AA1C ...Repeated for IEC 61850 GOOSE analog input 5
AA23 ...Repeated for IEC 61850 GOOSE analog input 6
AA2A ...Repeated for IEC 61850 GOOSE analog input 7
AA31 ...Repeated for IEC 61850 GOOSE analog input 8
AA38 ...Repeated for IEC 61850 GOOSE analog input 9
AA3F ...Repeated for IEC 61850 GOOSE analog input 10
AA46 ...Repeated for IEC 61850 GOOSE analog input 11
AA4D ...Repeated for IEC 61850 GOOSE analog input 12
AA54 ...Repeated for IEC 61850 GOOSE analog input 13
AA5B ...Repeated for IEC 61850 GOOSE analog input 14
AA62 ...Repeated for IEC 61850 GOOSE analog input 15
AA69 ...Repeated for IEC 61850 GOOSE analog input 16
AA70 ...Repeated for IEC 61850 GOOSE analog input 17
AA77 ...Repeated for IEC 61850 GOOSE analog input 18
AA7E ...Repeated for IEC 61850 GOOSE analog input 19
AA85 ...Repeated for IEC 61850 GOOSE analog input 20
AA8C ...Repeated for IEC 61850 GOOSE analog input 21
AA93 ...Repeated for IEC 61850 GOOSE analog input 22
AA9A ...Repeated for IEC 61850 GOOSE analog input 23
Table B–10: MODBUS MEMORY MAP (Sheet 45 of 70)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT