ANSI / SIA CP-01 REQUIREMENTS
To meet SIA CP-01 requirements –
Minimum System Requirements: 1 control panel; 2 keypads (or 1 keypad per partition for multi-partitioned systems)
Remote arming shall NOT be enabled in SIA classified installations.
Off-premise transmission must be in the SIA format.
The Abort window and Entry Delay must not exceed 1 minute.
CAUTION – A call waiting cancel on a non-call waiting line will prevent successful connection to the central station.
CP-01 Feature
Description
Feature Description
as shown in manual
Program
Loc
Seg / Opt
Factory
Default
CP-01 Required
Setting
Exit Time Exit 1 Delay
24
2
60
45 – 240 sec.
Exit 2 Delay
24
4
60
45 – 240 sec.
Progress Annuncation / Disable
– for Silent Exit
Silent Keypad Option
9 3 2
All annunciators enabled Allowed
(individual keypads may be disabled)
Exit Time Restart This feature is non-programmable in the panel. Enabled
Auto Stay Arm on Unvacated
Premises
Auto Bypass
23 1 / 3
Enabled Enabled
Exit Time and Progress
Annunciation / Disable
– for Remote Arm
This feature is non-programmable in the panel. -- Exit time and progress are always
enabled.
Enabled (may be disabled for remote arming)
Entry Delay(s) Entry 1 Delay
24 1
30 30 – 240 sec.
Entry 2 Delay
24 3
30 30 – 240 sec.
Abort Window
– for Non-Fire Zones
Dialer Delay
40 8
30 Enabled
(may be disabled by zone/ zone
type)
Abort Window Time
– for Non-Fire Zones
Dialer Delay
40 8
30 15 – 45 sec.
NOTE:
Combined
Abort
window and
Entry Delay
must not
exceed 1
minute.
Abort Annunciation
This feature is non-programmable in the panel. -- Flashing Cancel LED goes off when
disarming.
Enabled
Cancel Annunciation Cancel
23 3 / 6
Enabled Enabled
Duress Feature Duress
44
Disabled
Disabled
Cross Zoning
2 Trips on Cross Zone
37
5 / 4
Disabled
Required
Keypad sounds on Cross Zone trip
39 5
Disabled
Zone Type Characteristic
111
3 / 4
Disabled
Programmable Cross Zoning Time
Cross Zone Time
40
6
5 minutes
Allowed
Swinger Shutdown Swinger Shutdown Count
38 n/a
Enabled for 1 trip For all non-fire zones, shut down at 1–2 trips
Swinger Shutdown Disable Swinger Shutdown Count
38 n/a
Enabled for 1 trip Allowed
Fire Alarm Verification Fire Alarm Verification Time
40 9
Disabled Required (depends on panel & sensors)
Call Waiting Cancel
Must be programmed as part of
the phone number
0 n/a
n/a Required (depends on user phone line)
Default Changes (from prior
versions):
Recent Closing
23 3 / 7
Enabled
Exit Error
23 3 / 8
Enabled
Power Up Delay
40 3
60 sec.
IMPORTANT
NOTE:
UL requirements
take priority over
SIA requirements.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6 and is the answer not in the manual?

GE NetworX NX-6 Specifications

Operating Power IconOperating Power
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Loop Specifications IconLoop Specifications
loop resistance for standard loop300 Ohms Maximum
loop resistance for 2-wire smokes30 Ohms Maximum
loop response500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
LED Keypad Specifications IconLED Keypad Specifications
led keypad current draw130 mA max.
led keypad dimensions width6.4"
led keypad dimensions height4.0"
led keypad dimensions depth1.1"
NX-148E LCD Keypad Specifications IconNX-148E LCD Keypad Specifications
nx-148e lcd keypad current draw110 mA max.
nx-148e lcd keypad dimensions width6.4"
nx-148e lcd keypad dimensions height5.3"
nx-148e lcd keypad dimensions depth1.0"
Enclosure and Shipping IconEnclosure and Shipping
metal enclosure dimension width11.25"
metal enclosure dimension height11.25"
metal enclosure dimension depth3.50"
shipping weight9 lbs.