18
STANDARD (Default) ZONE TYPES
Zones can be programmed to be one of twenty different zone types (configurations). Zone Types # 17 - 20 can be used
for wireless or hardwired zones using European double EOL configuration. Table 1.1 lists the standard (default) zone
types. These twenty zone types can be customized by programming locations 110-149.
Table
1.1
STANDARD ZONE TYPE DESCRIPTIONS
"1" DAY ZONE - Instant when system is armed trouble zone when system is disarmed.
"2"
24-HOUR AUDIBLE - Creates an instant yelpin
g
siren alarm re
g
ardless of the armed state of the control
panel.
"3"
ENTRY/EXIT DELAY 1-
A trip will start entry delay 1. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
"4"
FOLLOWER WITH AUTO- BYPASS DISABLED - This zone will be instant when the system is armed and no
entry or exit delays are bein
g
timed. It is delayed durin
g
entry and exit delay times. This zone will not
automatically bypass even if enabled in Segment 1 of Location 23.
"5"
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED -
This zone will be instant when the system is
armed and no entry or exit delay is bein
g
timed. It is delayed durin
g
entry and exit delay times. This zone will
automatically bypass if enabled in Segment 1 of Location 23.
"6" INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
"7"
24-HOUR SILENT - Creates an instant silent alarm re
g
ardless of the armed state of the control panel. It will
not display on the keypad.
"8"
FIRE - This zone will li
g
ht the Fire LED and sound the temporal siren each time the zone is shorted. It will
also rapidly flash the Fire LED indicating a trouble if the zone is open.
"9"
ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack of a trip durin
g
exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
"10"
24 HOUR SILENT SUPERVISED-
Creates an instant silent alarm regardless of the armed state of the control
panel. It will display on the keypad.
"11"
KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that it
resides in each time the zone is shorted. Keyswitch arming will report as user #99.
"12"
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be instant when the system is
armed and no entry or exit delay is bein
g
timed. It is delayed durin
g
entry and exit delay times. If a "Cross
Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an
instant alarm. This zone will automatically bypass when enabled in Segment 1 of Location 23.
"13"
INSTANT ENTRY GUARD -
This zone creates an instant alarm whenever it is tripped and the Stay LED is
off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
"14"
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will
bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip durin
g
exit delay will
enable the Automatic Bypass or Instant mode if so programmed.
"15"
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is
armed and no entry or exit delays are being timed. It is delayed durin
g
entry/exit delay times. This zone will
bypass when the "Group Bypass" command is entered at the keypad. This zone will automatically bypass if
enabled in Segment 1 of Location 23.
"16"
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped and
the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad.
"17"
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip durin
g
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This Zone Type can be used
to enable tamper on a wireless transmitter.
"18"
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when the
system is armed and no entry or exit delay is bein
g
timed. It is delayed durin
g
entry and exit delay times.
This zone will automatically bypass if enabled in Segment 1 of Location 23.
This zone type can be used to
enable tamper on a wireless transmitter.
"19"
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the
Armed LED is on. This zone type can be used to enable tamper on a wireless transmitter.
"20"
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip durin
g
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used
to enable tamper on a wireless transmitter.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6 and is the answer not in the manual?

GE NetworX NX-6 Specifications

Operating Power IconOperating Power
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Loop Specifications IconLoop Specifications
loop resistance for standard loop300 Ohms Maximum
loop resistance for 2-wire smokes30 Ohms Maximum
loop response500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
LED Keypad Specifications IconLED Keypad Specifications
led keypad current draw130 mA max.
led keypad dimensions width6.4"
led keypad dimensions height4.0"
led keypad dimensions depth1.1"
NX-148E LCD Keypad Specifications IconNX-148E LCD Keypad Specifications
nx-148e lcd keypad current draw110 mA max.
nx-148e lcd keypad dimensions width6.4"
nx-148e lcd keypad dimensions height5.3"
nx-148e lcd keypad dimensions depth1.0"
Enclosure and Shipping IconEnclosure and Shipping
metal enclosure dimension width11.25"
metal enclosure dimension height11.25"
metal enclosure dimension depth3.50"
shipping weight9 lbs.

Related product manuals