EasyManuals Logo

GE NetworX NX-6V2 User Manual

GE NetworX NX-6V2
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
NX-6V2 Control 3
Table of Contents
I. GENERAL DESCRIPTION.................................................................................................................................................................4
II. ORDERING INFORMATION ............................................................................................................................................................ 4
III. BOARD INSTALLATION ................................................................................................................................................................... 4
IV. NX-6V2 WIRING DIAGRAM ............................................................................................................................................................. 5
V. TERMINAL DESCRIPTIONS ............................................................................................................................................................ 6
NETWORX KEYPAD MAXIMUM WIRE RUN .................................................................................................................................. 6
VI. PROGRAMMING THE LED KEYPADS .......................................................................................................................................... 7
KEYPAD ADDRESS AND PARTITION .............................................................................................................................................. 7
CHANGING USER CODES: ................................................................................................................................................................. 7
ASSIGNING AUTHORITY LEVEL:..................................................................................................................................................... 8
VII. PROGRAMMING THE CONTROL .................................................................................................................................................. 8
ENTERING THE PROGRAM MODE ................................................................................................................................................... 8
SELECTING THE MODULE TO PROGRAM...................................................................................................................................... 8
PROGRAMMING A LOCATION ......................................................................................................................................................... 8
EXITING A LOCATION ....................................................................................................................................................................... 9
EXITING THE PROGRAM MODE....................................................................................................................................................... 9
VIII. PROGRAMMING DATA TYPES.......................................................................................................................................................9
NUMERICAL DATA ............................................................................................................................................................................. 9
FEATURE SELECTION DATA ............................................................................................................................................................ 9
PROGRAMMING EXAMPLE............................................................................................................................................................. 10
IX. LOADING FACTORY DEFAULTS ................................................................................................................................................. 11
X. ENROLLING MODULES AND KEYPADS .................................................................................................................................... 11
XI. L QUICK START INSTALLATION ........................................................................................................................................... 11
XII. PROGRAMMING LOCATIONS...................................................................................................................................................... 11
REPORTING EVENTS TO PHONE NUMBER 1 ............................................................................................................................... 12
REPORTING EVENTS TO PHONE NUMBER 2 ............................................................................................................................... 13
REPORTING EVENTS TO PHONE NUMBER 3 ............................................................................................................................... 14
XIII. DEFAULT ZONE TYPES (CONFIGURATIONS) .........................................................................................................................16
XIV. PROGRAMMING WORKSHEETS ................................................................................................................................................. 31
XV. GLOSSARY......................................................................................................................................................................................... 39
XVI. APPENDIX 1 ....................................................................................................................................................................................... 43
XVII. APPENDIX 2 ....................................................................................................................................................................................... 44
XVIII. APPENDIX 3 ....................................................................................................................................................................................... 45
XIX. APPENDIX 4 ........................................................................................................................ ERROR! BOOKMARK NOT DEFINED.
XX. LOCAL TELEPHONE COMPANY INTERFACE INFORMATION........................................................................................... 46
XXI. NOTICES............................................................................................................................................................................................. 47
XXII. UNDERWRITERS LABORATORIES INFORMATION............................................................................................................... 48
XXIII. ANSI / SIA CP-01 REQUIREMENTS .............................................................................................................................................. 50
XXIV. SPECIFICATIONS............................................................................................................................................................................. 52

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.