NX-6V2 Control    31 
XIV. PROGRAMMING WORKSHEETS 
 
(Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the 
L symbol.) 
 
 
LOC  PG  DESCRIPTION  DEFAULT  PROGRAM DATA 
L 
0 11 PHONE 1  14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14 
__ __ __ __ __ __ __ __ __ __ 
__ __ __ __ __ __ __ __ __ __ 
L 
1  11  PHONE 1, ACCOUNT CODE  10 - 10 - 10 - 10 - 10 - 10  _ _ _ _ _ _ 
L 
2  11  PHONE 1, REPORTING FORMAT  0  _ 
L 
3  12  PHONE 1, DIAL ATTEMPTS 
BACKUP CONTROL 
8 
0 
_ 
_ 
  4  12  PHONE 1, SELECTING EVENTS TO REPORT TO PHONE 1 
      Segment 1   (Circle Numbers To Program)  Segment 2   (Circle Numbers To Program) 
  1 =  Alarms and Restores 
2 =  Open/Close 
3 =  Bypass 
4 =  Zone Trouble 
5 =  Power Trouble (AC Failure or Low Battery) 
6 =  Siren & Telephone Fault 
7 =  Test Reports 
8 =  Program, Download, & Log Full 
1 =   Tampers 
2 =  Short Circuit & Ground Fault 
3 =  Sensor Lost 
4 =  Sensor Low Battery 
5 =  Expander Trouble 
6 =  Failure To Communicate 
7 =  Zone Activity Monitor 
8 =  Reserved 
  5  12  PHONE 1, SELECTING WHICH PARTITIONS REPORT TO PHONE 1 
  Segment 1   (Circle Numbers To Program) 
      1 =  Partition 1 
2 =  Partition 2 
  
L 
6 12 PHONE 2  14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14 
__ __ __ __ __ __ __ __ __ __ 
__ __ __ __ __ __ __ __ __ __ 
L 
7  12  PHONE 2, ACCOUNT CODE  10 - 10 - 10 - 10 - 10 - 10  _ _ _ _ _ _ 
L 
8  13  PHONE 2, REPORTING FORMAT  0  _ 
  9  13  PHONE 2, DIAL ATTEMPTS 
 BACKUP CONTROL 
8 
0 
_ 
_ 
  10  13  PHONE 2, SELECTING EVENTS TO REPORT TO PHONE 2 
      Segment 1   (Circle Numbers To Program)  Segment 2   (Circle Numbers To Program) 
      1 =  Alarms and Restores 
2 =  Open/Close 
3 =  Bypass 
4 =  Zone Trouble 
5 =  Power Trouble (AC Failure or Low Battery) 
6 =  Siren & Telephone Fault 
7 =  Test Reports 
8 =  Program, Download, & Log Full 
1 =  Tampers 
2 =  Short Circuit & Ground Fault 
3 =  Sensor Lost 
4 =  Sensor Low Battery 
5 =  Expander Trouble 
6 =  Failure To Communicate 
7 =  Zone Activity Monitor 
8 =  Reserved 
  11  13  PHONE 2, SELECTING WHICH PARTITIONS REPORT TO PHONE 2 
  Segment 1    (Circle Numbers To Program) 
      1 =  Partition 1 
2 =  Partition 2 
  
 12 13 PHONE 3  14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14 
__ __ __ __ __ __ __ __ __ __ 
__ __ __ __ __ __ __ __ __ __ 
  13  14  PHONE 3, ACCOUNT CODE  10 - 10 - 10 - 10 - 10 - 10  _ _ _ _ _ _ 
  14  14  PHONE 3, REPORTING FORMAT  0  _ 
  15  14  PHONE 3, DIAL ATTEMPTS 
BACKUP CONTROL 
8 
0 
_ 
_ 
  16  14  PHONE 3, SELECTING EVENTS TO REPORT TO PHONE 3 
      Segment 1   (Circle Numbers To Program)  Segment 2   (Circle Numbers To Program) 
      1 =  Alarms and Restores 
2 =  Open/Close 
3 =  Bypass 
4 =  Zone Trouble 
5 =  Power Trouble (AC Failure or Low Battery) 
6 =  Siren & Telephone Fault 
7 =  Test Reports 
8 =  Program, Download, & Log Full 
1 =  Tampers 
2 =  Short Circuit & Ground Fault 
3 =  Sensor Lost 
4 =  Sensor Low Battery 
5 =  Expander Trouble 
6 =  Failure To Communicate 
7 =  Zone Activity Monitor 
8 =  Reserved