LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
73 24
GROUND FAULT / GROUND FAULT RESTORE
0-0-0-0 _ _ _ _
74 24
EXPANDER TROUBLE / EXP TROUBLE RESTORE
0-0-0-0 _ _ _ _
75 24 FAILURE TO COMMUNICATE 0-0 _ _
76 24 LOG FULL COMMUNICATOR CODE 0-0 _ _
77 24 OPENING CODE COMMUNICATOR CODE
Segment 1: Partition 1 Opening Code 0 _
Segment 2: Partition 2 Opening Code 0 _
78 24 CLOSING COMMUNICATOR CODE
Segment 1: Partition 1 Closing Code 0 _
Segment 2: Partition 2 Closing Code 0 _
79 24 AUTOTEST COMMUNICATOR CODE 0-0 _ _
80 24 RECENT CLOSING AND EXIT ERROR 0-0 _ _
81 24
START PROGRAMMING / END PROGRAMMING
0-0-0-0 _ _ _ _
82 24 END DOWNLOAD 0-0-0-0 X X _ _
83 24 CANCEL COMMUNICATOR CODE 0 _
84-87 24 RESERVED 0-0-0-0 Reserved
88 25 PARTITION 1, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _
89 25 PARTITION 2, ACCOUNT CODE 10-10-10-10-10-10 _ _ __ _ _
90 25 PARTITION 2, FEATURE AND REPORTING SELECTION
Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables auto instant
8 = Reserved
Segment 3
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
Segment 4
1 =Late to Close / Early to Open 2-8 =Reserved
Segment 5 Reserved
91 25 PARTITION 2 ENTRY/EXIT TIMERS
Segment 1: Entry Time 1 0 _
Segment 2: Exit Time 1 0 _
Segment 3: Entry Time 2 0 _
Segment 4: Exit Time 2 0 _
Segment 5 & 6 Reserved
92- 109
25 RESERVED
110 25 ZONE TYPE 1 ALARM EVENT CODE 8 _
111 25 ZONE TYPE 1 CHARACTERISTIC SELECT
Segment 1
1 = Fire (enable for fire zone)
2 = 24-Hour (enable for non-fire 24 hour)
3 = Keyswitch zone
4 = Follower (
enable for burg zones that are
instant during non-entry times
)
5 = Delay 1 zone (enable to follow Timer 1 Entry/Exit times)
6 = Delay 2 zone (enable to follow Timer 2 Entry / Exit times)
7 = Interior (Enable for auto bypass or stay arming)
8 = Local Only (enable if zone is not to be reported)
Segment 2
1 = Keypad audible on alarm.
2 = Yelping siren on alarm.
3 = Temporal siren on alarm.
4 = Chime.
5 = Bypassable.
6 = Group Shunt.
7 = Force armable.
8 = Entry Guard.
Segment 3
1 = Fast Loop Response.
2 = Double End of Line Tamper zone.
3 = Trouble zone (Day zone).
4 = Cross Zone.
5 = Dialer Delay zone.
6 = Swinger zone.
7 = Restore reporting.
8 = Listen-In.
Segment 4
1 = Zone Activity Monitor.
2 = End of Line Resistor Defeat.
3 = Enables zone to act as request to exit
input / disables for alarm activation.
4 = Enables zone to act as access entry point (
Do not enable this
segment unless configured with Access Control.
)
5-8 = Reserved.
Segment 5 RESERVED