EasyManuals Logo

GE NetworX NX-8-EUR User Manual

GE NetworX NX-8-EUR
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
[*]-[5] CHANGING USER CODES
1. Enter [*]-[5]-[master code]- the “Ready” LED will flash.
2. Enter the 3 digit user number (always 3 digits, such as “003” for user 3)- the “Ready” LED
will illuminate steadily.
3. Enter the new user code designated for the person in question - the “Ready” LED will
flash, indicating that the code has been accepted. If the code is rejected, the sounder will
beep 3 times.
4. If another user code needs to be programmed, return to step 2.
5. Press [#] while the “Ready” LED is flashing in order to exit the user code programming
mode.
6. Pressing four times (for 4-digit code) can erase a user code or six times (for 6-digit code)
the “Cancel” key.
[*]-[6] ASSIGNING AUTHORITY LEVEL
1. Enter [*]-[6]-[master code]- the “Ready” LED will flash.
2. Enter [3 digit user number] (always 3 digits, such as 003 for user 3)- the “Ready” LED will
illuminate steadily and the “Instant” LED will flash. Refer to the chart below for the
description of each LED. Turn on the LED for the features that you want.
LED ATTRIBUTES IF LED 8 IS OFF LED ATTRIBUTES IF LED 8 IS ON
1 Reserved 1 Activate output 1
2 Arm only 2 Activate output 2
3 Arm only after closing window 3 Activate output 3
4 Master arm/disarm (can program
other codes)
4 Activate output 4
5 Arm/disarm code 5 Arm/disarm code
6 Allowed to bypass zones (see location
23)
6 Allowed to bypass zones (see location
23)
7 Code will send open / close reports 7 Code will send open / close reports
8 If this LED is on, LED’s 1-7 will use the
chart too the right
8 If this LED is off, LED’s 1-7 will use the
chart on the left
1. Enter [*]: The “Instant” LED will illuminate steadily.
This moves you to the ‘partition enable’. (This tells the system which partition this user
can arm/disarm.) LED’s 1-8 will light up for each partition that the user is authorised to
arm/disarm. To change any of these numbers, press 1-8 to permit or deny access to the
user. (Example: If LED 2 is lit, then the user has been assigned access to that partition. By
pressing the [2] key, the LED will go out, indicating the user has been denied access to
that partition.)
2. Enter [*]:
This brings you back to step 2 above. At this point, you may enter another user number to
which you can assign attributes. You may continue this procedure until you have
assigned authority levels to all user numbers; otherwise, you may press the [#] key to exit
the assigning authority level program.
NX-8-EUR Installation manual Page 16 02/07/06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-8-EUR and is the answer not in the manual?

GE NetworX NX-8-EUR Specifications

General IconGeneral
BrandGE
ModelNetworX NX-8-EUR
CategoryControl Panel
LanguageEnglish

Related product manuals