Appendix A Product Certifications and Installation Guidelines
For public disclosure
GFK-2847W
EMC Installation and Operation Considerations
This equipment is intended for industrial use only and complies with a minimum level of EMC performance as defined by
EN
61000-6-2 and EN 61000-6-4 standards. To meet these requirements, the following installation and operation
considerations were taken into account:
Shielding USB cables
Limiting RS-232 cables to 15 m (49.2 ft) in length
Using Audio ports only during operational maintenance
Although these considerations were deliberated during testing, actual EMC environments vary greatly. Therefore, these
considerations may not be necessary. Likewise, additional measures, such as filtering, wire separation, and cable routing,
may need to be considered to ensure intended operation of the overall system.