EasyManua.ls Logo

GEA ECOVENT - Page 96

GEA ECOVENT
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spring-to-open valve (NO) without control head T.VIS
INFO Removal step: remove the clamp connection between the upper and mid-
dle housing
Tools
●
Jaw wrench, a/f 10/11
●
Jaw wrench, a/f 12/13
●
Jaw wrench, a/f 13/17
●
Jaw wrench a/f 24
1. Mount the hinged clamps (43) between the upper and middle housing.
®
Observe torques, see
9.6.1 Tightening torques
.
2. Release the manual emergency actua-
tor (H) and remove.
®
V
alve disk is raised.
See also the additional operating in-
structions for the manual emergency
actuator.
H
43
96 / 128 - 9.6 Installing the valve
0000000607 - 002 - EN-GB

Table of Contents