Tightening torques [Nm] [lbft]
Clamps on the control top 1 0.7
Cap 1 0.7
Clamp connection
M6 9 6.6
M8 22 16.2
M10 45 33
9.6.2 Assembling the valve insert from individual parts
Mounting the clamp connection depends on how the valve is congured:
●
see section
Spring-to-close valve (NC) with control head T.VIS
●
see section
Spring-to-close valve (NC) without control head T.VIS
●
see section
Spring-to-open valve (NO)
WARNING
Risk of injury when mounting sharp-edged parts
●
Do not put your hand into the valve housing.
ATTENTION
Sensitive valve parts
Damage to the valve parts can lead to a malfunction.
●
Protect the valve parts against impact stress.