EasyManua.ls Logo

GEA ECOVENT - Assembling the Valve Insert from Individual Parts

GEA ECOVENT
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tightening torques [Nm] [lbft]
Clamps on the control top 1 0.7
Cap 1 0.7
Clamp connection
M6 9 6.6
M8 22 16.2
M10 45 33
9.6.2 Assembling the valve insert from individual parts
Mounting the clamp connection depends on how the valve is congured:
see section
Spring-to-close valve (NC) with control head T.VIS
see section
Spring-to-close valve (NC) without control head T.VIS
see section
Spring-to-open valve (NO)
WARNING
Risk of injury when mounting sharp-edged parts
Do not put your hand into the valve housing.
ATTENTION
Sensitive valve parts
Damage to the valve parts can lead to a malfunction.
Protect the valve parts against impact stress.
76 / 128 - 9.6 Installing the valve
0000000607 - 002 - EN-GB

Table of Contents

Related product manuals