4. For optional version with INI holder:
4.1 Screw
the mounting for the
proximity switch (C) into the ac-
tuator using the jaw wrench on
the wrench at surface (C3).
4.2 Screw the switch bar (139) into
the mounting for proximity
switch (C) on the wrench at
surface (139.1) using a jaw
wrench (a/f 17).
4.3 Mount the proximity switches
(C1, C2).
®
Observe torques, see
9.6.1 Tighten-
ing torques
.
Þ
The clamp connection is mounted.
98 / 128 - 9.6 Installing the valve