10.4.7 Disassemble rotors and mechanical seals
Tools and equipment:
•
Klüber paste UH1 96-402
•
Puller for mechanical seals
•
Lock screw (included with delivery)
•
Socket wrench for rotor bolts
Contact for tool order: Section 1.3, Page 9.
Fig.26: Puller for mechanical
seals
Fig.27: Lock screw
Fig.28: Socket wrench
Disassemble rotors and mechanical seals
Unscrew and remove the cap nuts (0927.06).
Fig.29: Cap nuts
Remove the back plate (0161.01) and the O-ring
(0412.54).
Fig.30: Back plate
Malfunctions / repairs
Repair
BA.280.YYY.001.GB_4