____________________ _
ADL300-EPCv2- User Guide Page 45 of 64
If set to 0 the brake feedback alarm is signalled immediately.
If set to 1 the possible brake feedback alarm is signalled at the end of the travel: this allows the lift car to
reach the floor in case of a faulty brake status signal.
Setting of the delay between the signalling of the Brake Feedback alarm condition and activation of the
alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If the
alarm is removed within the time set in this parameter, the drive will not activate it.
Setting of the delay between the signalling of the Contactor Feedback alarm condition and activation of
the alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If
the alarm is removed within the time set in this parameter, the drive will not activate it.
Setting of the delay between the signalling of the Door Feedback alarm condition and activation of the
alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If the
alarm is removed within the time set in this parameter, the drive will not activate it.
Brake hold off ms INT16 1000 RW FVS
5.9.9 11576
Cont hold off ms INT16 1000 RW FVS
Door Hold off ms INT16 1000 RW FVS