ADL300-EPCv2- User Guide Page 46 of 64
Rephaser alarm status.
A digital signal is sent to the Output 3708 (see menu 5.7 INPUT/OUTPUT Outputs Table) in case of
Synchronous motors, and to the bit 11 Lift Status Word in case of asynchronous motors, when the
elevator go through each floor. In this way is possible to track by a signal the passage of the car through
a floor. The duration of this signal is configurable by this parameter.
Number of floors
Setting of the source for the floor call command:
0 Digital Input
1 Parameter
2 Fieldbus -> MS3
Floor call setting parameter. Active if the floor call source is selected as "Parameter"
The destination floor value is displayed
The number of floors is displayed.
5.9.11 12190
On Speed Limit On BIT OFF R FVS
IP Signal Time ms INT16 100 50 4000 RW FVS
Number of floors INT16 7 1 15 RW FVS
Floor call UINT16 0 1 15 RW FVS
Floor Destination UINT16 0 R FVS
Numero Piano UINT16 0 R FVS