EasyManuals Logo

gefran TPD32-EV-CU series User Manual

gefran TPD32-EV-CU series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #442 background imageLoading...
Page #442 background image
—————— TPD32-EV ——————
442
Parameter No. Format
Value Access via
min max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
FLUX REGULATION (FIELD CURRENT REGULATION)
Enableuxreg
ON(Enabled)
OFF(Disabled)
497 U16 0 1 Enabled Enabled
ü
R/W
1
0
ID
H
L
-
Fluxregmode
Constantcurrent
Voltagecontrol
Externalcontrol(OFF)
ExtdigitalFC
ExtwiredFC
469 U16 0 2 Const.
current
0
Const.
current
0
ü
R/Z
0
1
2
3
4
- -
Enableuxweak
ON(Enabled)
OFF(Disabled)
498 U16 0 1 1 1
ü
R/W
1
0
ID
H
L
-
Speed-0fweak
ON(Enabled)
OFF(Disabled)
499 U16 0 1 0 0
ü
R/W
1
0
- -
Fluxreference[%]
500 Float* 0.0 100.0 0.0 0.0
ü
R QA -
Fluxcurrent[%]
234 Float* 0.0 100.0 - -
ü
R QA -
Outvltlevel
921 Float* 0.00 100.0 100.0 100.0
ü
R/W IA,QA R/W
FCcurrefhyst
1522 U16 1 100 5 5
ü
R/W - -
FClimitramp
Disabled(0)
Enabled(1)
411 U16 - - Disabled Disabled
ü
R/W - -
FClmtramptime[ms]
888 U16 200 10000 800 800
ü
R/W - -
FLUX REGULATION (FIELD CURRENT REGULATION) \ Flux \ if curve
Ieldcnst40
916 Float 0.0 100.0 40.0 40.0
ü
R/Z -
Ieldcnst70
917 Float 0.0 100.0 70.0 70.0
ü
R/Z -
Ieldcnst90
918 Float 0.0 100.0 90.0 90.0
ü
R/Z -
Setux/if
919 U16 0 1 0 0
ü
Z/C -
Resetux/if
920 U16 0 1 0 0
ü
Z/C -
Nomuxcurr[A]
374 Float 0.5 70.0 S S
ü
R/Z - -
Motornomux
280 Float 0.00 P374 P374 P374
ü
R/Z - -

Table of Contents