Page 30
Operation of the power generator
Then pull the starter grip hard.
Repeat both steps until the engine starts.
If the choke is used, put it slowly back into the OPEN position while the engine is warming up.
Switch the connected consumers on.
NOTE
Allow the starter cord to run back slowly so that the starter is not damaged!
5.6.2. Stopping
Set the main switch to "0" position.
The engine switches o.
Remove all consumers and cables from the socket outlets.
5.7. Operation under especially dicult climatic conditions
NOTE
Operating materials: see the section on "Prerequisites for trouble-free operation"
5.7.1. Lubricating oil
Select the viscosity (SAE) according to the ambient temperature at the installation site. Refer to the
operating manual of the engine manufacturer.
5.7.2. Utilisation at high altitudes
At altitudes above 1500 m, petrol with a minimum of 85 octane/85 AKI (89 RON) is acceptable. In the
case of Otto engines, a setting for high altitudes is necessary so that the performance is maintained.
Running the engine without this setting will result in performance loss, increased fuel consumption
and higher emissions. Consult an authorised dealer for information about the high-altitude setting. It
is not recommended to use the engine with the high-altitude setting at altitudes below 760 m.

Table of Contents