Maintenance / Repairs ZA08
Maintenance schedule
The following components or modules are subject to a maintenance
schedule:
Check for powder residues
and clean
Motor case in the reciprocator
base
Check for powder dust
deposits and clean
Check for wear and tension
Check for free movement and
wear
Check for wear and deposits
and clean it
All electrical screw and clamp
connections
The specified intervals are based on operation of 8 hours per day.
During assembly, cleaning, maintenance and commissioning when
close to live components, an electric shock can cause serious
injury or death.
► All work must be carried out only by trained personnel and when
no power is applied!
► Verify that the parts are deenergized by means of a voltmeter!
► The vertical axis has to be free of load!
The motor gear box is self-lubricating and maintenance-free!
Observe the contamination of the enclosure – strong contamination on
the outside can increase the operating temperature of the drive unit!
Therefore, clean the drive unit from time to time (with a vacuum cleaner
etc.). If the drive unit gearbox has to be changed for any reason, the
complete unit has to be replaced!