ISOLATING
DIFFERENT
POWER
SOURCES
Conductors from the junction box must terminate
in
a
double pole, double throw transfer switch (Figure 28}.
An
alternate method
for
isolating different power
sources
is
by using
an
isolating receptacle (Figure 29
on
Page 25}. Whichever method
you
use, you must
be
certain that both power sources are NOT connect-
ed
at the same time.
POWER
SUPPLY
CORD
The power supply cord must comply with
all
applica-
ble
codes, standards and regulations.
It
must
be
large
enough to handle the full amperage to which it will
be
subjected.
FLEXIBLE
COI\IDIIIT
POWER
SUPPLY
GROUND
FAULT
CIRCUIT
INTERRUPTERS
The National Electric Code (NFPA 70, 551-7} requires
that
you
install
ground
fault
circuit
interrupters
(GFCis)
on
all external and some internal electrical
receptacles. Contact your manufacturer or dealer for
recommendations.
DOUBLE
POLE/
DOUBLE
THROW
SWITCHING.
DEVICE
.
VEHICLE
WIRING
JOAMP
CORD~
MAII\1
BREAKER
HACR
BREAKERS
'==::r:J-----t--=-_rOR
AIR
-24-
VEHICLE
A-C
DISTRIBUTION
PANEL
CONDITIONERS
~ff::=t=::=::::~FCI
BREAKERS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems NP-30G Series and is the answer not in the manual?

Generac Power Systems NP-30G Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelNP-30G Series
CategoryPortable Generator
LanguageEnglish

Related product manuals