11
RESIDENTIAL/COMMERCIAL
LIQUID-COOLED ENGINE GENERATOR
LIQUID COOLED INSTALLATION
RTS TRANSFER SWITCH
UTILITY SUPPLY FROM
SERVICE DISCONNECT
CUSTOMER LOAD
(DISTRIBUTION PANEL)
800A-3 PHASE SHOWN
NOTE:
N3, E3 AND T3 WIRES ARE ONLY
USED ON 3 PHASE SYSTEMS.
CONNECTION PANEL
NEUTRAL BLOCK
GROUND
194
23
N1
N2
E1 E2
NOTE:
MATCH WIRE
TERMINAL NUMBERS
NUMBERS TO
ON
N1
N2
T1/LINE
NEU
178
183
23
194
N1 N2 (N3)
NEUTRAL
GROUND
BLOCK
(T3)T1 T2
(E3)E1 E2
(E3)
CUSTOMER
CONTROL
WIRING SUPPORT
23
194
0
3 PHASE
SINGLE PHASE
N1
N2
0
DETAIL "A"
9940
POTTER & BRUMFIELD
KUP-11D55-12
12VDC
1/3HP, 120VAC
10A, 240VAC
MADE IN MEXICO
063617-F
67210X
063925-T
063925-T
063925-T
063925-T063925-T
063925-T063925-T
063925-T 063925-T
E1 E2
NOTE: INSTALLATION TO BE DONE BY A
LICENSED ELECTRICIAN AND MUST
MEET ALL NATIONAL, STATE AND
LOCAL ELECTRICAL CODES.
0D2907-T
M4X10STUD-T
0D2907-T
M4X10STUD-T
0D2907-T
M4X10STUD-T
0D2907-T
M4X10STUD-T
M8X35 PEM STUD
0F7808-T
M8X35 PEM STUD
0F7808-T
M8X35 PEM STUD
0F7808-T
M8X35 PEM STUD
0F7808-T
WS16-0F
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0H3797B-S
0F7807B-S
10-32X5/16
0H3797A-F
0F7807B-S
10-32X5/16
0D2908-S
M4X15STUD
0D2907-S
M4X10STUD
0F7806-T
M4 WHIZ
0F7806-T
M4 WHIZ
0F7806-T
M4 WHIZ
050299E-S
M6X20
0C8112A-S
3/8X16
0F7807C-S
0F7807B-S
10-32X5/16
0H3797A-F
0F7807B-S
10-32X5/16
0H3797B-S
3/8-16 LH
64101-S
3/8X16
0F7807C-S
050299E-S
0H3797B-S
0H3797A-F
0D2908-S
M4X15STUD
0H3797A-F
0F7807B-S
10-32X5/16
0F7807B-S
10-32X5/16
10-32X5/16
0F7807B-S
10-32X5/16
0F7807B-S
0A9457X
050299E-S050299E-S 050299E-S
050299E-S050299E-S050299E-S
050299E-S050299E-S 050299E-S
050299E-S050299E-S050299E-S
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0D2905-S
M5X12STUD
0D2908-S
M4X15STUD
0D2907-S
M4X10STUD
0D2907-S
M4X10STUD
0D2907-S
M4X10STUD
0F7808-S
M8X35 PEM STUD
0F7808-S
M8X35 PEM STUD
0F7808-S
M8X35 PEM STUD
0H3797A-SH
0H3797A-SH
0H3797A-SH
3/8 x 2
49572-S
3/8 x 2
49572-S
FIELD INSTALLED
TRANSFORMER
LOCATION
BUSSMAN-BBS-5
5A 600V
FUSE
OR EQUIV.
REPLACEMENT
0E4415G
LEFT INSIDE VIEW
FRONT VIEW
A7822-T
600MCM
0D6584-T
A7822-T
600MCM
A7822-T
600MCM
0D6584-S
1/4 STL
22097-S
1/4-20 x 3/4
22287-S
600MCM
A7822-S
M6
049811
BT2
BT2
TRANSFER SWITCH
RATED CURRENT
XXXXXX
72112
RATED VOLTAGE
600 VAC CSA
480 VAC UL
800 AMP
TRIP
SELECT
MANUAL OPERATION
THE "SELECT" WITH A SCREWDRIVER.
IN THE DIRECTION WHILE PUSHING
DO NOT OPERATE WHILE THE SWITCH IS UNDER LOAD.
OPERATE IN THE DIRECTION
SET MANUAL HANDLE ON "M" AND OPERATE
PUSH THE "TRIP" WITH A SCREWDRIVER.
SET MANUAL HANDLE ON "M" AND
ST
M
CLOSE STANDBY
CLOSE UTILITY
TRIP OPEN
A2A1 B1
A2A1 B1 AT1
AT1B2
B2
AT2 BT1
AT2 BT1
STANDBY
B
UTILITY
A
091472-17T
WIRE DUCT 1.25X1.5X17"
30A, 600V
D2806-T
D2572-T
30A, 600V
Interconnection Drawing No. 0K3675-A Electrical Data