EasyManua.ls Logo

Generac Power Systems TAS-200

Generac Power Systems TAS-200
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
This manual should remain with the unit.
TTS Series
TAS-200
200A Automatic Transfer Switch
Owner's Manual
Model 006310-0 120/240V, 1-phase
Model 006312-0 120/208V, 3-phase
Model 006314-0 120/240V, 3-phase
ļ‚‹
Only qualified electricians or contractors
should attempt installation!
Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems TAS-200 and is the answer not in the manual?

Generac Power Systems TAS-200 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelTAS-200
CategorySwitch
LanguageEnglish

Summary

Safety Rules

General Hazards

Discusses general hazards associated with the transfer switch operation and installation.

General Information

1.2.3 Automatic Transfer Switch

Explains the automatic transfer of electrical loads between normal and standby power sources.

Installation

1.7 Safe Use of Transfer Switch

Emphasizes safety rules and compliance with codes for using the transfer switch.

2.4 Connecting Power Source and Load Lines

Instructions for safely connecting power source and load lines to the transfer switch.

Operation

3.1 Functional Tests and Adjustments

Outlines how to inspect and perform functional tests on the installed transfer switch system.

3.2 Manual Operation of ATS Contactor

Provides step-by-step instructions for manually operating the ATS contactor.

3.3 Voltage Checks

Guides on performing voltage checks to ensure compatibility with the transfer switch.

3.4 Electrical Operation Testing

Describes how to test the electrical operation of the transfer system via the HMI.

3.8 Sequence of Operation

Explains the automatic sequences of operation for power source transfers.

3.9 Sequence of Operation Settings

Lists and explains the configurable parameters and default values for operation sequences.

3.10 Human Machine Interface (HMI)

Introduces the HMI, its accessibility, and its use for viewing status and changing settings.

3.10.2 HMI Configuration Menu

Explains how to navigate the HMI to select different configuration screens.

3.10.3 HMI Transfer Switch Settings #1

Details settings for Inphase, Transfer Delay, and System Voltage/Phase selection.

3.10.4 HMI Transfer Switch Settings #2

Covers settings for Utility Fail and Pickup voltage thresholds.

3.10.5 HMI Transfer Switch Settings #3

Details settings for Engine Warm Up, Cool Down, and Minimum Run Timers.

3.10.7 HMI Exercise Setup

Describes how to configure exercise day, time, duration, and transfer settings.

3.10.8 HMI Manual Tests

Accesses test functions for normal and fast test sequences of the transfer switch.

3.10.11 HMI Voltage Measurement Maintenance

Guides on calibrating utility and generator voltage inputs using the HMI.

Maintenance

4.2 Clean and Inspect Transfer Switch

Details annual cleaning and inspection procedures for the transfer switch.

Related product manuals