Models FL3100/3101
34
R - indicates Read Only Access R/W - indicates Read/Write Access
Master
Reg I/O Refer to
Parameter
Function Type Scale Access Addr Addr Section
Comm 1 Indicates present Data Format Value (0 - 3) R/W 000C 4013 7.7.12
Data Format (Comm 1)
(8N-1, 8E-1, 8O-1, 8N-2)
UV Indicates No. of UV Signal Value 8-Bit R 000D 4014 7.7.13
Sig Count Pulses within 500 ms
IR Indicates No. of IR Signal Value 8-Bit R 000E 4015 7.7.14
Sig Count Pulses within 500 ms
UV Fault Indicates Total No. of UV Value 8-Bit R 000F 40416 7.7.15
Total COPM Faults
IR Indicates Total No. of IR Value 8-Bit R 1010 4017 7.7.16
Fault Total COPM Faults
Remote Remotely Resets the Alarm Bit 1-Bit R/W 0011 4018 7.7.17
Reset & Warn Relays
Remote Remotely Activates Alarm Bit 1-Bit R/W 0012 40419 7.7.18
Alarm Test Test
Clear COPM Clears UV/IR COPM Fault Bit 1-Bit R/W 0013 40020 7.7.19
Faults Counters
Comm 1 & 2 Total # of Receive Errors Value 8-Bit R 0020 40033 7.7.20
Total
Receive
(Comm 1 & 2)
Errors
Comm 1 or 2 Bus Activity Rate in % Decimal (0-100%) R 0021 40034 7.7.21
Bus Activity Of this Addressed Node vs. Hex (0-64)
Rate % Other Addressed Nodes
(Comm 1 or 2)
Comm 1 & 2 Total # of Function Code Value 8-Bit R 0022 40035 7.7.22
Function Errors (Comm 1 & 2)
Code Errors
Comm 1 & 2 Total # of Starting Addresses Value 8-Bit R 0023 40036 7.7.23
Starting Errors (Comm 1 & 2)
Address
Errors