Sensor Type | Flame Detector |
---|---|
Field of View | 90 degrees |
Operating Temperature | -40°C to +75°C (-40°F to +167°F) |
Humidity | 0 to 95% non-condensing |
Output | 4-20 mA |
Approvals | FM, ATEX, IECEx |
Certifications | CE |
Housing Material | Stainless Steel |
Details warranty coverage for defects in workmanship and material for the Models FL3100/FL3101.
Installation and maintenance must be performed by skilled personnel.
Verifies wiring, connections, and mounting before power-up, and checks outputs after.
Outlines periodic testing and calibration procedures for field devices.
Details annual verifications for wiring, connections, mounting, and system operation.
Instructions for mounting the detector using swivel mount or bracket hardware.
Describes startup sequence, LED indicators, and testing with TL100/TL103 lamps.
Explains what fire is and the function of UV/IR and UV flame detectors.
Lists necessary tools for installation, including wrenches and screwdrivers.
Provides guidance on selecting optimal locations for detector installation.
Details how to mount the detector and seal conduit entries.
Explains how to make wire connections to the terminal block.
Details protection circuits for relay contacts when switching AC/DC loads.
Describes the functionality and ratings of the Alarm and Warning relays.
Details the Fault relay functionality and how to use the Alarm Reset terminal.
Explains the Alarm Test terminal function and the 0-20mA analog output.
Details cable specifications and power supply requirements.
Covers MODBUS interface connections and chassis ground.
Explains wiring detectors to fire cards/panels.
Guidelines for terminating cables in non-hazardous areas, including grounding.
A checklist of items to verify before starting the system operation.
Describes the process for powering up and testing the flame detectors.
Explains how to configure detector settings using DIP switches.
Outlines routine maintenance like sensitivity checks and cleaning.
Provides instructions for cleaning the detector's optical components.
Explains how to verify detector functionality and sensitivity.
Details the operation and charging of the TL100 UV test lamp.
Describes the operation and recharging of the TL103 UV/IR test lamp.
Provides recommendations for storing the flame detectors.
Introduces the troubleshooting guide and highlights safety precautions.
Lists common problems, their causes, and recommended solutions.
Details the steps for final assembly of the detector.
Lists contact information for General Monitors' offices worldwide.
Explains how to select and set the baud rate for MODBUS communication.
Details the selectable data formats for MODBUS communication.
Describes the query and response message structure for reading status.
Explains the query and response message structure for writing commands.
Lists supported function codes and describes exception responses.
Details exception codes and command register locations.
Provides detailed information on command register parameters and their functions.
Covers Analog, Mode, and Status/Error registers.
Explains the UV/IR Only detection registers.
Covers Model Type and Software Revision registers.
Details COPM Fault and EEPROM Override registers.
Describes Options, Comm 1 Address, Baud Rate, and Data Format settings.
Details Comm 1 Data Format and UV/IR Signal Count registers.
Explains Fault Total, Remote Reset, Alarm Test, and error count registers.
Covers Bus Activity Rate and Communication Error registers.
Details Receive Errors and RXD CRC Errors registers.
Explains Overrun Errors and Noise Flag Errors registers.
Details Noise Flag Errors and Framing Errors registers.
Covers Message Interval, Comm 2 errors, address, and baud rate.
Details the Comm 2 Data Format settings.
Explains the fundamental principles of UV and UV/IR flame detection.
Details the operation of the UV/IR detector, including COPM and Alarm Test.
Lists system specifications like application, detector location, and waterproof rating.
Provides data on detector field of view and sensitivity range.
Details electrical specifications, supply voltage, and relay contact ratings.
Covers environmental conditions, approvals, and accessories.