Regeneration
Mode
A-01 Meter Delay: Regeneration happens when the capacity reaches zero and the preset time of
regeneration is reached.
A-02 Meter Immediate: Regeneration happens when the capacity reaches zero.
A-03 Intelligent Meter Delay (manufacturer default preset): Do not change unless consulting a water
treatment professional first.
A-04 Intelligent Meter Immediate: The same function as A-02 but the capacity is determined by
entering the Total Resin Capacity and Feed Water Hardness. The control valve automatically calculates
the gallons for regeneration.
A-05 Remaining Compare: Compares current usage with previous 365 day daily usage to intelligently
determine when regeneration will occur. Regeneration starts at the set regeneration time.
A-06 By Day (timer): Service days count down to zero (0) and regeneration starts at the set
regeneration
time.
A-07 Filter Meter: Filter mode, regeneration occurs when the capacity reaches zero and the preset time
for regeneration is reached.