EasyManuals Logo

Genesis Upflow-NHW User Manual

Genesis Upflow-NHW
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
4. Pre-Installation Checklist
IMPORTANT NOTICE
Read through the instructions thoroughly and obtain all materials and tools before proceeding with the installation. Be sure to follow
all applicable national, state, county and local plumbing codes and regulations.
All plumbing and electrical work should be performed by an accredited professional to ensure all local, state, and municipal guidelines
are met.
During cold weather it is recommended that the installer warm the valve to room temperature before operating.
For outdoor installation ensure that system cannot freeze and is protected from direct sunlight and weather conditions including rain.
Outdoor weather cover can be added for additional weather protection of the control valve. Warranty coverage does not include
damage due to weather or acts of God.
Required Operating Conditions
Working Conditions
Working Pressure
20psi ~ 120psi
Water Temperature
35 °F ~ 125 °F
Working Environment
Environment Temperature
35 °F ~ 125 °F
Relative Humidity ≤95%
Power Source
< 100-240VAC / 50-60Hz
Inlet Water Quality
Turbidity
< 2FTU
Hardness
< 60 grains per gallon
Chlorine
< 0.1ppm
Iron
2+
< 0.3ppm
CAUTION
Do not exceed 120 psi water pressure.
Do not exceed 35° C / 125° F water temperature.
Do not subject unit to freezing conditions.
Failure to use this product within the described conditions may void the warranty.
Genesis Upflow Valves & Systems Service Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genesis Upflow-NHW and is the answer not in the manual?

Genesis Upflow-NHW Specifications

General IconGeneral
BrandGenesis
ModelUpflow-NHW
CategoryControl Unit
LanguageEnglish

Related product manuals