12 Basic Programming
BASIC PROGRAMMING Default
dF
DEFAULT:
Y indicates that all the set values correspond to the defaults.
no indicates that one or more set values are different from the
defaults.
Select
Y if you wish to restore the default configuration.
Y
Ct
MASTER-SLAVE CONFIGURATION (§ 10):
MA = board in MASTER mode:
SL = board in SLAVE mode:
Li
If the board is in SLAVE mode, some functions will
not be displayed: LO, PA, Pb, bu, PF, Ph, OP,
t, IP, t1, Ob, SP.
MA
LO
OPERATING LOGICS (§ 7.5):
E = Semi-automatic
EP = Semi-automatic Step-by-Step
A = Automatic
AP = Automatic Step-by-Step
S = Automatic Safety
b = Semi-automatic B
C = Dead-man
E
PA
PAUSE TIME A
(displayed only with automatic logics)
It is the total opening pause time.
Adjustable from
00 to 59 sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate minutes and
tens of seconds (separated by a dot) with adjustment in steps of
10 seconds, up to a maximum of 9 min and 50 s.
Li
E.g.: if the display indicates 2.5, the time is 2 min
and 50 sec.
20
Pb
PAUSE TIME B
(displayed only with automatic logics)
It is the partial opening pause time.
Adjustable from
00 to 59 sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate minutes and
tens of seconds (separated by a dot) with adjustment in steps of
10 seconds, up to a maximum of 9 min and 50 s.
Li
E.g.: if the display indicates 2.5, the time is 2 min
and 50 sec.
20
FO
MOTOR POWER:
01 = minimum force
50 = minimum force
50
So
OPENING SPEED:
01 = minimum speed
10 = maximum speed
08
Sc
CLOSING SPEED:
Regulates the closing speed of the motor.
01 = minimum speed
10 = maximum speed
08
ro
DECELERATION DURING OPENING:
Sets the opening pre-limit switch deceleration space in cm
00 = minimum deceleration space
99 = maximum deceleration space.
50
BASIC PROGRAMMING Default
rc
DECELERATION DURING CLOSING:
Sets the closing pre-limit switch deceleration space in cm
00 = minimum deceleration space
99 = maximum deceleration space
50
bu
BUS DEVICE REGISTRATION:
Li
See § 7.6.
--
M1
ELECTRIC MOTOR ACTUATION IN DEAD-MAN MODE
Li
See § 7.7.
Mt
tL
SET-UP
Li
See § 7.8.
St
AUTOMATION SYSTEM STATUS:
Y To save and exit from programming mode.
no To exit from programming mode without saving
Press button
F to confirm; when finished, the display reverts to
the automation status display:
00 = Closed
01 = Open
02 = Stationary then opens
03 = Stationary then closes
04 = Paused
05 = Opening
06 = Closing
09 = Pre-flashing then opens
10 = Pre-flashing then closes
14 = Obstacle during opening
15 = Obstacle during closing
Y