39XLp Installation & Configuration, June 2010
Maintenance
• To keep a smooth Y-axis movement it is
recommended to clean and slightly oil both
round ways at regular intervals (2-3 weeks
depending on usage). Make sure you do not
touch the Code Strip with oil (use a small
piece of oiled rag to sweep the round ways).
• Make sure the Y Encoder Strip is free of dust
and debris. If not then the head may take-off
at a high speed and slam into the Cleaning
Station.