EasyManua.ls Logo

Gesipa taurus 3 - Spent Mandrel Not Evacuated; Warranty; CE Declaration of conformity

Gesipa taurus 3
12 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
GB
12. CE Declaration of conformity
We hereby declare that the design and construction of the tool named below, as well as the
version that we have put on the market, complies with applicable fundamental health and
safetyrequirementsstipulatedinEUdirectives.Toolmodicationsmadewithoutourauthori-
sation shall render this declaration void. The safety information in the product documentation
provided must be observed. This document must be retained.
TAURUS
®
1-4
2006/42/EG
DIN EN ISO 12100:2011
DIN EN ISO 11148-1:2012
DIN EN 82079-1:2013
Authorised documentation representative:
GESIPA Blindniettechnik GmbH
Nordendstraße 13-39
D-64546 Mörfelden-Walldorf
pp Dr. Richard Gärtner
11. Warranty
The applicable terms and conditions of guarantee shall apply and can be viewed under follow-
ing link: www.gesipa.com/agb
10.2 Spent mandrel is not evacuated
Cause Corrective measures
Spent mandrel container (No. 36) full Empty (Point 7.5)
Wrong nosepiece (No. 1) used Replace according to table (Point 6)
Nosepiece (No. 1) worn Replace
Spent mandrel jammed in jaws (No. 5)
Clean jaws (No. 5) and jaw housing (No. 4) and oil
sliding surfaces; replace if worn (Point 8.2)