EasyManua.ls Logo

Gewiss JOINON I-CON BASIC - User Manual

Gewiss JOINON I-CON BASIC
218 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
JOINON WALLBOX
I-CON BASIC
Manuale di utilizzo ed installazione - User and installation manual - Manuel
d’installation et d’exploitation - Manual de uso e instalación - Installations- und
Bedienungsanleitung - Manual de instalare și instalare -Használati és telepítési
útmutató - Gebruiks- en installatiehandleiding
IT
UNITÀ DI RICARICA VEICOLI ELETTRICI
JOINON WALLBOX I-CON BASIC - JOINON WALLBOX I-CON BASIC RECHARGING UNIT FOR ELECTRIC
VEHICLES - UNITÉ DE RECHARGE DE VÉHICULES ÉLECTRIQUES JOINON WALLBOX I-CON BASIC -
UNIDAD DE CARGA DE VEHÍCULOS ELÉCTRICOS JOINON WALLBOX I-CON BASIC - LADESTATION FÜR
ELEKTROFAHRZEUGE JOINON WALLBOX I-CON BASIC - UNITATE DE REÎNCĂRCARE VEHICULE
ELECTRICE JOINON WALLBOX I-CON BASIC - JOINON WALLBOX I-CON BASIC ELEKTROMOS JÁRMŰ
TÖLTŐEGYSÉG - OPLAADEENHEID VOOR ELEKTRISCHE VOERTUIGEN JOINON WALLBOX I-CON BASIC
EN
ES HU
FR DE RO NL

Table of Contents

Questions and Answers

  • A
    Amanda LangAug 12, 2025
    What to do if my Gewiss Accessories station is OFF?
    • J
      johnstantonAug 12, 2025
      If your Gewiss Accessories charging station displays 'Station OFF', verify the power supply leading to the station. Also, check that the circuit breaker protection on the electronic board protection panel is functioning correctly and ensure the 12V power supply to the electronic board is working.
  • D
    Debbie VasquezAug 15, 2025
    How to fix Gewiss Accessories Error 4?
    • N
      Nichole CarpenterAug 15, 2025
      If your Gewiss Accessories displays Error 4, check the signal from the electronic board to the contactor to ensure the board is controlling the contactor. If the board isn't controlling it, verify the contactor contacts aren't jammed. If necessary, replace the device.
  • A
    Amanda DennisAug 20, 2025
    What to do if Gewiss Accessories shows Error 15?
    • T
      Tammy BrockAug 20, 2025
      If a vehicle has been connected and your Gewiss Accessories shows Error 15, contact the vehicle's manufacturer for assistance.
  • E
    Eric CarsonAug 23, 2025
    How to troubleshoot Gewiss Accessories Error 8?
    • R
      Russell JonesAug 23, 2025
      If your Gewiss Accessories displays Error 8, check the Modbus line connection, the power supply to the energy meters. Ensure the energy meters are working properly and that the component on the Modbus line is numbered correctly.
  • J
    Julie WardAug 27, 2025
    What does Error 14 mean on Gewiss Accessories?
    • K
      Kelly HoweAug 27, 2025
      If your Gewiss Accessories displays Error 14, remove the cable and try again. If the error persists, replace the cable.
  • L
    lindapierceAug 31, 2025
    What to do for Gewiss Accessories Error 13?
    • J
      James HarperAug 31, 2025
      If your Gewiss Accessories displays Error 13, remove the recharging cable from the vehicle and wait to begin a new session. If the problem continues, contact the vehicle manufacturer.
  • P
    Pamela MatthewsSep 3, 2025
    How to resolve Gewiss Accessories Error 10?
    • P
      Patricia HendersonSep 3, 2025
      If your Gewiss Accessories displays Error 10, disconnect the power supply to the charging station and leave it switched off for at least 2 minutes. Then, reconnect the power supply and wait for the station to reconnect to the platform.
  • J
    Joshua PetersonSep 7, 2025
    How to fix Gewiss Accessories Error 6?
    • K
      Kimberly LynchSep 7, 2025
      To resolve Error 6 on your Gewiss Accessories, manually check the mobility of the pin by moving the red lever on the back of the type 2 socket-outlet locking motor.

Summary

Manual Information

Field of Application

Lists specific charging station models covered by this manual.

Intended Users

Defines qualified personnel and recommends professional installation for safety.

Symbols Guide

Explains the meaning of various symbols used throughout the manual for clarity.

Regulatory Compliance

EU Directive Compliance

Details compliance with Low Voltage, EMC, and RED directives for market access.

Ingress Protection Rating

States the IP55 rating, indicating protection against dust and water.

Pollution Degree Classification

Specifies the pollution degree (Level 3) as per IEC 60664-1 standard.

Connector Types

Lists available connector configurations, such as IEC 62196-2 Type 2.

Safety Guidelines

Safety Conditions and Warnings

Outlines general safety rules, electrical shock risks, and mandatory manual review.

People Hazard Warnings

Warns about potential crushing and limb injuries from improper handling or positioning.

Device Hazard Warnings

Advises against touching sensitive electronic components and disconnecting live terminals.

Personal Protective Equipment (PPE)

Lists essential PPE like safety footwear, helmet, and dielectric gloves for safe operation.

Delivery and Storage

Delivery Instructions

Recommends keeping the device packaged until the moment of installation.

Device Identification

Explains how the serial number serves as the unique identifier for the device.

Transport Damage Reporting

Procedure for reporting damage incurred during transport within 5 days.

Storage Recommendations

Provides guidelines for proper storage to prevent deterioration and lists ambient conditions.

Device Handling Procedures

Transport Handling

Fundamental ergonomic advice for safe lifting and moving of the device.

Packaging Removal and Disposal

Emphasizes careful packaging handling and outlines disposal methods for materials.

Installation Preparation

Environmental Site Selection

Guidance on choosing an accessible location, avoiding corrosive environments.

Operating Environmental Conditions

Details required ambient conditions like temperature and relative humidity for operation.

Mounting Surface Requirements

Specifies the need for a solid, vertical wall and suitable fastening hardware.

Opening the Casing

Step-by-step visual instructions on how to safely open the device casing.

Closing the Casing

Step-by-step visual instructions on how to securely close the device casing.

Installation and Connection

General Installation Rules

Covers essential requirements for installation environment, workspace, and cabling.

Basic Model Installation Guide

Specific instructions tailored for the basic JOINON WALLBOX I-CON model.

Device Mounting Methods

Details methods for fixing the device to a wall or a pole using brackets.

Power Supply Connection

Outlines required protection devices and wiring specifications for power connection.

Operation Modes and Features

Autostart Mode Operation

Explains the AUTOSTART mode and power selection using a dedicated selector.

RFID Mode Operation

Describes RFID mode for session activation and termination using RFID cards.

Cloud OCPP Connectivity

Details CLOUD mode, connecting to platforms via OCPP for remote control.

Status LED Indicators

Explains the meaning of various RGB LED colors and patterns for status indication.

Recharging Process

Autostart Charging Steps

Details the sequence of actions and LED statuses for initiating an AUTOSTART charge.

Parking Mode Operation

Explains how charging sessions are activated and managed using RFID cards in Parking mode.

RFID Card Management

Describes methods for adding new RFID cards and deleting existing ones from the local list.

RFID Session Initiation

Details the steps and LED feedback for starting a recharging session with an RFID card.

Cloud Parking Mode

Explains CLOUD mode connection via OCPP and its benefits for users and owners.

Troubleshooting Common Faults

Firmware Update Procedure

Parameter Modification

Disconnecting from Mains

Preventive Maintenance

Residual Current Device Checks

Recommends periodic checks (every 6 months) of residual current circuit breakers for proper function.

Gewiss JOINON I-CON BASIC Specifications

General IconGeneral
BrandGewiss
ModelJOINON I-CON BASIC
CategoryAccessories
LanguageEnglish

Related product manuals