EasyManuals Logo

GEZE Slimdrive EMD-R User Manual

GEZE Slimdrive EMD-R
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Slimdrive EMD / -F / -F-IS / Invers
12
Cleaning and maintenance
5 Cleaning and maintenance
CAUTION!
Danger of injury due to impact and crushing!
X
Disconnect the drive from the 230 V mains network before carrying out cleaning work.
X
Secure door leaves against accidental movement before carrying out cleaning work.
X
Installation, maintenance and repair work must be performed by properly trained personnel authorised by
GEZE.
5.1 Cleaning
What is to be cleaned? How is it to be cleaned?
Safety sensor close (SIS) (e.g. light sensors)
X
Wipe with moist cloth
Glass surfaces
X
Wipe with a cold vinegar/water mixture; then dry.
Stainless surfaces
X
Wipe with non-scratching cloth
Painted surfaces
X
Wipe with water and soap
Anodised surfaces
X
Wipe with non-alkaline potassium soap (pH value 5.57)
Display programme switch
X
Wipe with soft cloth. Do not use a cleaning agent
5.2 Maintenance check
The owner must ensure that the system functions properly. To guarantee perfect operation, the door system
must be serviced regularly by a service technician.
Maintenance must be carried out at least once a year or according to the maintenance display on the display
programme switch.
If a dot appears in the bottom right-hand part of the display, maintenance is due.
X
Notify a service technician.
GEZE oers maintenance contracts with the following services:
à Inspection of fastening elements for rm t
à Performance of miscellaneous adjustment work
à Performance of operational checks
à Checking all the safety and control equipment of the door system
à Lubrication of all the moveable parts
5.3 Testing by a competent expert
In accordance with the "Guidelines for windows, doors and gates" (ASR A1.7 and GUV 16.10) Section 6, power-
operated doors must be inspected for safety by a trained professional before initial commissioning and at least
once a year.
GEZE oers the following services:
Inspection and operational checks of all safety and control equipment in accordance with the requirements in
the test log for power-operated windows, doors and gates; Sliding doors and sliding gates ZH 1/580.2 edition.

Other manuals for GEZE Slimdrive EMD-R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GEZE Slimdrive EMD-R and is the answer not in the manual?

GEZE Slimdrive EMD-R Specifications

General IconGeneral
BrandGEZE
ModelSlimdrive EMD-R
CategoryDoor Opening System
LanguageEnglish

Related product manuals