EasyManua.ls Logo

Ghost Controls Ghost Pro Series - Monitored Safety Devices - Photo Eyes (AXPE); Accessory Signal Input Logic; Open Input Terminal (OPEN); Closing-Reverse Input (CLS-RVRS)

Ghost Controls Ghost Pro Series
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63
HARDWIRED ACC.
©Ghost Controls
®
2020
Active — Signal must go from INACTIVE then ACTIVE for the system to recog-
nize the input and respond accordingly.EX: OPEN > STOP > CLOSE > STOP >
OPEN >...
OPEN INPUT OPEN: Use this terminal for Ghost Controls Vehicle Detector
(AXXV).
Active — OPENS gate to full open limit and prevents it from closing,
if it remains active.
CLOSINGREVERSE INPUT CLSRVRS: Use this terminal with photo eye
beams or safety edge.
Active — Prevents gate from CLOSING or reversing to open limit if it was
CLOSING.
OPENINGREVERSE INPUT OPNRVRS: Use this terminal with photo eye beams or safety edge.
Active — Prevents gate from OPENING or reversing to close limit if it was OPENING.
MONITORED SAFETY DEVICES PHOTO EYES AXPE
NOTE
Please refer to manufacturers manual or website for more detailed instructions on how to connect and use accessories with
your gate opener.
TERMINALS TO USE FOR REVERSE OPENING:
PWR = Switched 12 Volts (+)
MS–OP1 = Photos beam’s output for 1st arm open-direction protection
MS-OP2 = Photos beam’s output for 2nd arm open-direction protection
COM = Battery
IF THE BEAM IS BLOCKED OR DEVICE IS DISCONNECTED
Gate can not be open if idle
Gate will reverse direction and run to the closed position if it was opening
TERMINALS TO USE FOR REVERSE CLOSING:
PWR = Switched 12 Volts (+)
MS-CL1 = Photos beam’s output for close-direction protection
COM = BATTERY NEGATIVE
IF THE BEAM IS BLOCKED OR DEVICE IS DISCONNECTED
Gate can not be closed if idle
Gate will reverse direction and run to the open position if it was closing