Alarms 41
Code no. 576017
Rev. nº 02/0415
11
INPUT TEMPERATURE PROBE FAULT
Fault in the system detecting the input temperature into the dryer drum.
Input temperature values outside the set range.
Probable cause:
Fault in the detection system.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.
12
OUTPUT TEMPERATURE PROBE FAULT
Fault in the detection system for the output temperature of the dryer drum.
Output temperature values outside the set range.
Probable cause:
Fault in the detection system.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.
13
INPUT THERMOSTAT ALARM (machines with electric heating only)
Disconnection of the safety thermostat controlling the input temperature.
Probable cause:
Input temperature control thermostat circuit open.
Fault in the detection system.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.
14
OUTPUT THERMOSTAT ALARM
Disconnection of the safety thermostat controlling the output temperature.
Probable cause:
Output temperature control thermostat circuit open.
Fault in the detection system.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.
15
ROTATION FAULT
Drum rotation fault.
Probable cause:
Obstruction, seizing or poor functioning of the transmission systems between the motor and the drum.
Overloading or excessively wet linen that exceeds the maximum power capacity of the motor.
Fault in the system detecting the drum rotation.
Procedure:
Check that the load is not excessive or that the linen is too wet.
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.